BioMedInformatics

NeuroScan: A Leakage-Audited Unified Model for Stroke Slice Classification on Multi-Source CT and Diffusion MRI with a Web–Android Prototype

Md. Atikur Rahman, Md. Anwar Hossain Rantu, Afsana Mim, Md. Zahidur Rahman, Jahirul Islam Babar, Abdullah Al Zubaer, Md. Nashid Al-Jamil, Mahmudul Hasan

Key points

From the paper's conclusion
  • A web–Android research prototype demonstrates inference; external validation is required before clinical use.

Abstract

Distinguishing ischemic from hemorrhagic stroke guides treatment, yet many classifiers rely on single-modality or single-source data and report leakage controls inconsistently. In this internal feasibility study, the NeuroScan model classified computed tomography (CT) slices as normal, ischemic or hemorrhagic and diffusion magnetic resonance imaging (MRI) slices as normal or ischemic, because the MRI sources did not include hemorrhages. Seven leakage-audited public sources (109,443 slices, 85,872 used for training) were partitioned by patient where identifiers existed. The final ConvNeXt-Tiny model, with 224 × 224-pixel neighboring-slice or paired-sequence input, was evaluated once on internally reused evaluation cohorts, held out of training but used in earlier development, so the results are optimistic internal estimates, not independent or external validation. Under the class-weighted rule, it reached 89.2% accuracy (95% CI 88.2–90.1) and 87.2% macro-F1 on 8930 pooled internal test slices, and 88.5% and 86.8% under the prototype’s plain argmax; areas under the receiver operating characteristic curve were 0.986 (hemorrhage on CT) and 0.963 (ischemia). Joint training gave no discrimination advantage over matched single-modality models. At least one slice received the patient’s lesion class in 94.7% of lesion-positive patients; without healthy controls, patient-level specificity is unknown. During development, adding within-source lesion-free slices raised Core-Penumbra Acute Ischemic Stroke Dataset (CPAISD) accuracy from 43.5% to 81.4%. Across five seeds, accuracy varied little (SD 0.3 points), but CPAISD ischemic recall ranged from 54.2% to 78.6% (final model highest). Gradient-weighted class activation maps did not reliably localize lesions. A web–Android research prototype demonstrates inference; external validation is required before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

NeuroScan: A Leakage-Audited Unified Model for Stroke Slice Classification on Multi-Source CT and Diffusion MRI with a Web–Android Prototype — Science Skim