From Presumed Post-Stroke Seizures to Probable Ventricular Tachycardia: Antiseizure Therapy, Diagnostic Misattribution and Human Oversight of Smartwatch ECGs-A Narrative Review.
Dimitrios A Vrachatis, Grigoris Maros, Konstantinos A Papathanasiou, Christos Piperis, Antonios A Argyris, Ioannis Nikolakakis, Theodore G Papaioannou
Department of Biomedical Engineering, Medical School, National and Kapodistrian University of Athens, 11528 Athens, Greece. · Cardiovascular Prevention & Research Unit, Clinic/Laboratory of Pathophysiology, Laiko Hospital, Medical School, National and Kapodistrian University of Athens, 11528 Athens, Greece.
Key points
From the paper's conclusion- We propose assigning these responsibilities explicitly, including when artificial intelligence informs interpretation or triage.
Abstract
Transient arrhythmias can produce episodes that resemble seizures, and an incorrect attribution can lead to treatment that does not address the underlying mechanism. This narrative review is informed by the case of a patient with haemorrhagic stroke and severe left ventricular dysfunction whose recurrent episodes were considered compatible with epileptic seizures and treated with levetiracetam. Episodes recurred despite treatment. Smartwatch electrocardiograms (ECGs) obtained by relatives had been labelled inadequate and were understood to show no abnormality. On cardiologist review, one showed a regular wide-complex tachycardia interpreted as probable ventricular tachycardia; a single lead could not exclude supraventricular tachycardia with aberrant conduction, and urgent tertiary assessment was advised. We discuss three connected issues. First, the clinical features and cardiac substrate that should prompt reconsideration of the diagnosis when episodes persist despite antiseizure therapy. Second, evidence, largely from atrial fibrillation studies, that unclassified wearable recordings often remain interpretable by clinicians, and the more limited evidence for ventricular arrhythmias. Third, the conditions under which such recordings reach clinical review, including digital health literacy, communication of uncertainty, and services that receive recordings and communicate the plan. We propose assigning these responsibilities explicitly, including when artificial intelligence informs interpretation or triage. These arrangements require evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Seizure detection using wearable electrocardiogram connected to a smartphone: a phase 3 clinical validation studyEBioMedicine · 2025
- Levetiracetam-Induced Ventricular Tachycardia: A Rare Adverse Reaction Warranting Caution in Patients with Atrial FibrillationNeurology India · 2026
- Catecholaminergic polymorphic ventricular tachycardia with diagnostic difficulty differentiating seizures from syncope: a case report.Frontiers in pediatrics · 2026
- Diagnostic accuracy of multivector smartwatch electrocardiography compared with conventional 12-lead ecgEuropean Heart Journal · 2026
- Wearable devices for detection of cardiac arrest: a prospective proof-of-concept studyEuropean Heart Journal · 2026
- Seizure quantification using wearable devices.Epilepsia · 2026