Do Global Vessel Descriptors Help Multi-Disease Fundus Classification? A Leakage-Controlled Ablation of Hybrid CNN-Transformer Models with External Testing.
Bensu Beğenilmiş, Hüseyin Yanık, Evren Değirmenci
Department of Electrical and Electronics Engineering, Institute of Applied Sciences, Mersin University, 33343 Mersin, Türkiye. · Department of Information Systems and Technologies, School of Applied Technology and Management, Mersin University, 33343 Mersin, Türkiye.
Key points
From the paper's conclusion- Results: The CNN–Transformer hybrid reached an internal macro-AUROC of 0.945 ± 0.002 and a mean external macro-AUROC of 0.830 ± 0.005, exceeding the CNN baseline internally, on ODIR-5K and on Mendeley (Holm-adjusted p ≤ 0.0045) but not on STARE or IDRiD; an average of separately trained CNN and Transformer models performed similarly (0.831).
Abstract
Background/Objectives: Retinal vessel features are often added to fundus classifiers without isolating their effect. We examined whether global vessel descriptors improve multi-disease fundus classification under leakage-controlled external testing. Methods: After a duplicate audit and field-of-view normalization, models were trained on RFMiD and APTOS with a partial-label mask and tested internally and on four external datasets (ODIR-5K, Mendeley, STARE, IDRiD) that were not used for training, threshold fitting or calibration. Fourteen arms were compared: nine architectures combining EfficientNet-B4, Swin-S and a vessel branch, a label-handling control, and four variants with vessel features from other segmenters; ten arms were trained with three seeds. Vessel descriptors came from segmenters trained on 14 DRIVE images, 14 FIVES images or 480 FIVES images. Paired differences were tested with a hierarchical bootstrap and Holm correction; all external comparisons are exploratory. Results: The CNN-Transformer hybrid reached an internal macro-AUROC of 0.945 ± 0.002 and a mean external macro-AUROC of 0.830 ± 0.005, exceeding the CNN baseline internally, on ODIR-5K and on Mendeley (Holm-adjusted p ≤ 0.0045) but not on STARE or IDRiD; an average of separately trained CNN and Transformer models performed similarly (0.831). Treating unassessed labels as negatives lowered ODIR-5K and Mendeley AUROC (-0.018 and -0.032). For the CNN vessel arm, FIVES test Dice of 0.662, 0.779 and 0.833 for the three segmenters was accompanied by mean external AUROC of 0.786, 0.792 and 0.805, with the clearest differences on STARE and Mendeley; no vessel arm exceeded its counterpart without vessels. Conclusions: Global vessel descriptors added no measurable value to the image backbones studied, and their effect was associated with the upstream segmentation pipeline, whose quality should therefore be reported.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond Multi-Stage Pipelines: A Label-Correlation Ensemble for Multi-Label Retinal Fundus Disease ClassificationarXiv · 2026
- A multi-class fundus disease classification framework based on self-supervised contrastive learning and dual-branch network.Frontiers in medicine · 2026
- Label Granularity and Evaluation Design in ODIR-5K: A Leakage-Controlled Benchmark with External Validation for Fundus Disease ClassificationDiagnostics · 2026
- Data-Quality-Aware Fundus Classification with Anatomy-Guided Glaucoma Assessment and Cross-Dataset EvaluationarXiv · 2026
- AI driven Hybrid CNN transformer model for early detection and severity assessment of diabetic retinopathyScientific Reports · 2026
- SSLVNet: an explainable multi-modal hybrid framework integrating self-supervised learning and vision transformers for multi-label classification of retinal diseases.Frontiers in artificial intelligence · 2026