Key points
From the paper's conclusion- Methods: In the current study, the in vitro cytotoxicity of three innovative 3D-printed resins (Tera Harz TC-85 DAC, TA-28, and TR-07, Graphy, Seoul, Republic of Korea) and two conventional thermoformed materials (Smart Track, Invisalign, Align Technology, USA, and TruGEN, Spark, Ormco, USA) was assessed by measuring the cell viability of human primary gingival fibroblasts (HGFs) exposed to specim
Abstract
Background/Objectives: Three-dimensional (3D)-printed clear aligners represent a new alternative for treating orthodontic malocclusions. However, their biocompatibility remains a critical factor requiring careful evaluation. Methods: In the current study, the in vitro cytotoxicity of three innovative 3D-printed resins (Tera Harz TC-85 DAC, TA-28, and TR-07, Graphy, Seoul, Republic of Korea) and two conventional thermoformed materials (Smart Track, Invisalign, Align Technology, USA, and TruGEN, Spark, Ormco, USA) was assessed by measuring the cell viability of human primary gingival fibroblasts (HGFs) exposed to specimens via direct contact. Results: The MTT assay revealed that, at 7 days, 3D-printed resins exhibited a statistically significant reduction in HGF metabolic activity compared to both the control group and the thermoformed groups (p < 0.0001). A similar overall biological trend was observed at 14 days, with no progressive impairment in HGF viability, indicating that the materials maintain a stable in vitro biocompatibility profile over time. Across both time points, cell viability levels remained within the 60-90% range, categorized as "slight cytotoxicity" according to Ahrari et al., while consistently exceeding the 70% threshold required for compliance with International Organization for Standardization (ISO) 10993-5 standards. Conclusions: While thermoformed materials are currently considered the conventional reference in orthodontics, the tested 3D-printed resins show promising in vitro results, aligning with their ongoing integration into clinical orthodontic practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Cytotoxic Potential of Thermoformed and In‐House Manufactured Three‐Dimensionally Printed Orthodontic AppliancesClinical and Experimental Dental Research · 2026
- Biocompatibility and Safety of 3D Printing Resins for Orthodontic Aligners: A Critical Review of Current EvidencePolymers · 2025
- Comparison of three dental resins for 3D printing of orthodontic appliances: Comparison of leaching, biocompatibility, and thermo-mechanical properties after post-curing and agingDental Materials · 2025
- In Vitro Cytotoxicity of Three Dimethacrylate-Based Photopolymer Resins for 3D-Printed Dental Restorations: A Qualitative Morphological Screening on Human Fibroblasts.Journal of functional biomaterials · 2026
- Advances in clear aligner therapy: comparative evaluation of the optical properties and bacterial adhesion of 3D direct-printed and thermoformed alignersProgress in Orthodontics · 2025
- Fit analysis of 3D-printed versus thermoformed clear aligners for labial tooth movement using micro-CT: an in vitro studyScientific Reports · 2026