An Anesthesia-Free Pharmacological Assay for Zebrafish Heart Failure Models Using a Microfluidic Platform.
Qiuyue Song, Fangrui Liu, Jinyan Zhao, Wenli Xie, Xianjun Fu, Kuo Xu
Research Institute of Marine Traditional Chinese Medicine (Qingdao Academy of Chinese Medical Sciences), The SATCM's Key Unit of Discovering and Developing New Marine TCM Drugs, Key Laboratory of Marine Traditional Chinese Medicine in Shandong Universities, Shandong University of Traditional Chinese Medicine, Qingdao 266114, China. · College of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan 250355, China.
Key points
From the paper's conclusion- This study presents a microfluidic platform designed to facilitate anesthesia-free, noninvasive in vivo photography of zebrafish heart failure models.
Abstract
Background: The zebrafish model is extensively utilized for phenotypic screening, particularly in heart failure research. However, traditional photography-based data collection requires tricaine methanesulfonate (MS-222) anesthesia, which can suppress cardiac function and introduce artifacts. This study presents a microfluidic platform designed to facilitate anesthesia-free, noninvasive in vivo photography of zebrafish heart failure models. Methods: Isoproterenol (ISO) induced heart failure in 1 day post-fertilization (dpf) zebrafish embryos. Larvae were assigned to three groups: Control (E3 embryo medium only), Model (1 mM ISO for 48 h from 1 dpf), and Positive (1 mM ISO + 10 μM propranolol for 48 h from 1 dpf). Subsequently, a microfluidic chip featuring tapered immobilization channels was adopted. The chip facilitated the photography and collection of cardiac function parameters from lateral and supine positions, including cardiac output (CO), blood flow velocity (BFV), ejection fraction (EF), stroke volume (SV), and fractional shortening (FS). All imaging was performed in completely independent parallel experiments, with no individual larva shared between the two imaging methods. Data obtained under hydrodynamic confinement were compared with those acquired under MS-222 anesthesia. Results: Cardiac parameters measured using the microfluidic platform were significantly higher than those under MS-222 anesthesia: CO (0.339 ± 0.032 vs. 0.279 ± 0.023 nL/s, p < 0.001), BFV (681 ± 53 vs. 604 ± 38 μm/s, p < 0.001), EF (10.3 ± 0.7% vs. 6.6 ± 0.7%, p < 0.001), SV (184,519 ± 12,822 vs. 97,979 ± 5306 μm3, p < 0.001), and FS (7.3 ± 1.8% vs. 3.7 ± 0.9%, p < 0.001). Strong correlations (R2 > 0.85, p < 0.0001) revealed that anesthesia underestimated parameters by 11.3-49.3%. Conclusions: Compared with the traditional anesthesia-based method, the microfluidic platform enables more precise cardiac parameter collection in a zebrafish heart failure model than when anesthesia is used, offering a reliable tool for phenotypic screening of zebrafish embryos.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-throughput heart rate sensing in freely moving zebrafish using a multi-well plate-based fluorescence microscope.Optics letters · 2026
- Direct exposure to tricaine methanesulfonate (MS-222) alters zebrafish visual response properties.Experimental eye research · 2026
- A 3-D printed microfluidic platform for flow-induced dechorionation, chorion filtration, and cell dissociation of zebrafish embryos.Lab on a chip · 2026
- Electrical Stunning does not affect Brain Tissue Integrity and Stress Response in Larval ZebrafishbioRxiv · 2026
- Comparative Evaluation of Propofol, Eugenol and MS-222 in Yellowtail Tetra Astyanax lacustris: Anesthetic Efficacy, Physiological Responses and Recovery Dynamics.Animals : an open access journal from MDPI · 2026
- Multidimensional Cardiac Phenotyping of Daphnia magna Enables One-Hour Effect-Based Screening of Aquatic Toxicity.Environmental science & technology · 2026