Mechanical Feasibility and Computational Efficiency of Constraint-Optimized Muscle Activations in Contact-Based Lateral Pinch Simulations
Joaquín L. Sancho-Bru, Néstor J. Jarque-Bou, Verónica Gracia-Ibañez
Key points
From the paper's conclusion- For future assistive device design, hybrid strategies may provide a useful compromise: constraint-based models can be used for efficient optimization followed by targeted validation using contact-based simulations to assess the mechanical feasibility and contact retention of candidate solutions.
Abstract
Background/Objectives: Musculoskeletal modeling is a critical tool for investigating hand biomechanics and designing assistive technologies. However, the formulation of the mechanical interaction between the hand and objects remains a challenge. This study investigates how constraint-based versus explicit contact-based formulations influence the prediction of maximal lateral pinch force and contact retention in an open-source hand model. Methods: Fifty optimal muscle activation patterns were generated using a constraint-based forward-dynamics optimization framework. These solutions were then re-evaluated in a contact-based model under four friction conditions (μ = 0.29, 0.50, 0.75, and 1.0), with detailed force, kinematic, and computational analyses focused on μ = 0.29 and μ = 1.0. We analyzed the occurrence of contact loss, force stabilization behavior, and the associated computational costs. Results: Constraint-based formulations identified consistent maximal lateral pinch force ranges but overestimated the system’s ability to maintain contact by neglecting friction and sliding. In contact-based simulations with μ = 0.29, 92% of solutions lost contact, often at early stages. While increasing friction improved short-term contact retention, 66% of solutions still failed to maintain contact by the end of the 0.50-s simulations at μ = 1.0. For a simulated duration of 0.20 s, median execution times for contact-based forward dynamics were 62–75 times those for constrained forward dynamics under the numerical settings used. Numerical sensitivity tests showed unchanged contact-loss classification and negligible changes in force histories after tightening the integration tolerance and reducing the maximum step size. Conclusions: There is a clear trade-off between physical realism and computational efficiency. While constraint-based models allow for efficient large-scale optimization, they may yield mechanically unfeasible results. For future assistive device design, hybrid strategies may provide a useful compromise: constraint-based models can be used for efficient optimization followed by targeted validation using contact-based simulations to assess the mechanical feasibility and contact retention of candidate solutions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integration of a smooth mesh-based contact pressure model into tracking and predictive simulationsbioRxiv · 2026
- Modeling intersegmental mechanics to reproduce physiologic coordination patterns of multi-joint finger movements.Journal of biomechanics · 2026
- Modelling the human-exoskeleton interaction interface - Benchmarking MuJoCo's deformable modelarXiv · 2026
- Mechanical Engagement and Contact in Bioinspired Embodied Robots: Task Feasibility, State Transitions, and Experimental AttributionBiomimetics · 2026
- A Physiologically Detailed Biomechanical Model of the Mouse Distal Forelimb for Simulation of Fine Motor ControlbioRxiv · 2026
- Modeling the Frictional Contact of Continuum Robots with Environments through Linear Complementarity ProblemarXiv · 2026