BiCE-MTXNet: Explainable Bidirectional Multi-Task Learning with Exact Branch Attribution for Dermoscopic Segmentation and Diagnosis
Khalid Alhussaini, Zaied Alhaj, Nabil Alrajeh
Key points
From the paper's conclusion- We present the Bidirectional Concept-Equilibrium Multi-Task Network (BiCE-MTXNet) for joint full-field segmentation and seven-class dermoscopic diagnosis.
Abstract
Joint dermoscopic analysis requires accurate lesion delineation, multi-class diagnostic discrimination, and transparent evidence attribution. We present the Bidirectional Concept-Equilibrium Multi-Task Network (BiCE-MTXNet) for joint full-field segmentation and seven-class dermoscopic diagnosis. Separate DINOv2-based feature pyramids process aspect-preserving 448×448 images, while a luminance occlusion gate weights valid support prior to quadratic Bernstein pooling across core, border, and context regions, combining 16 optical and morphological descriptors with 18 descriptor-regularized regional proxies. Diagnostic-conditioned feature-wise linear modulation and an anisotropic screened-Poisson equilibrium layer couple preliminary diagnostic signals to boundary estimation via residual-corrected mixed-precision Jacobi-preconditioned conjugate gradients with implicit differentiation, updating regional support for a second-pass five-branch additive readout that yields exact conditional branch Shapley values in one forward pass. Seven benchmark arms and seven retrained Stage-2 reduced architectures were evaluated across 4210 images spanning HAM10000 development and test splits, PH2, and ISIC 2016. Under matched four-view inference, BiCE-MTXNet achieved 95.41% development and 95.18% test Dice (retaining standalone segmentation overlap while improving test two-pixel boundary F1 by +9.68 and +2.51 percentage points over shared-encoder and one-way multi-task baselines), alongside 97.91% test macro-AUROC, 87.92% macro-average precision, and 81.08% macro-F1 (+7.74 percentage points over standalone classification). External Dice reached 92.95% on PH2 and 92.16% on ISIC 2016, with 87.50%PH2 melanoma sensitivity and 81.25% specificity and lower external deletion area under the curve (0.2282 versus 0.3002 for mask-only attribution, pHolm=0.0072). Controlled Stage-2 ablations confirm that decoupled spatial–semantic trunks and regional Bernstein pooling drive the primary contour and diagnostic gains, while the proxy, modulation, and equilibrium modules preserve standalone overlap and provide differentiable coupling and readout inspectability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MorphoNet: An Interpretable Hierarchical Deep Learning Framework for Multi-Class Skin Lesion Classification Using Dermoscopic Morphology.Bioengineering (Basel, Switzerland) · 2026
- Efficient Dermoscopic Lesion Segmentation via Multi-Directional State-Space Modeling and Frequency-Aware Boundary Refinement.Journal of imaging · 2026
- MedCORE: Criteria-Grounded Clinical Reasoning for Interpretable Medical Image DiagnosisarXiv · 2026
- Boundary-aware Mixture-of-Experts with Calibrated Bayesian Uncertainty for Skin Cancer Detection and Multi-class ClassificationInternational journal of intelligent engineering and systems · 2026
- PMCA ‐ UNet : A Parameter‐Efficient Skin Lesion Segmentation Network With Initial Feature Preservation and Parallel Multi‐Scale Convolutional AttentionInternational Journal of Imaging Systems and Technology · 2026
- Transfer Learning-Based Integrated Segmentation and Multi-Class Classification of Skin Lesion in Dermoscopic ImagesEPJ Web of Conferences · 2026