Bioengineering

Mechanical Properties of Native Human Aortic Valve Leaflets Under Uniaxial Tension: Associations with Age, Body Weight, and Cardiovascular Risk Factors

Vladimir Tsilibin, Fedor Tsvetkov, Dariya Zhulanova, Alex G. Kuchumov

Key points

From the paper's conclusion
  • Body weight was not associated with any parameter after accounting for clustering within donors (p ≥ 0.34).

Abstract

Background: The limited availability of comprehensive mechanical property data for native human aortic valve leaflets constrains the development of accurate finite element models and age-adapted prosthetic materials. This study aimed to characterize the uniaxial tensile behavior of human aortic valve cusps in the radial direction and to evaluate the influence of donor age, body weight, sex, coronary heart disease (CHD), and hypertension (HTN) on these properties. Methods: Fifty leaflet samples from 20 human donors were obtained from human cadavers of varying age, weight, and cardiovascular history, and tested within 24 h postmortem under physiological conditions (38 °C, 0.9% saline) at a displacement speed of 60 mm/min. Force–displacement data were converted to stress–strain curves, from which ultimate tensile strength, maximum strain, elastic moduli of the toe and linear regions, and strain energy were derived. Results: Nonlinear S-shaped curves with distinct toe and linear regions were observed in all samples. Mean values were as follows: ultimate tensile strength 2.41 MPa, failure strain 0.195, toe- and linear-region moduli 11.01 and 14.83 MPa, and strain energy density 0.209 MJ/m3. In linear mixed-effects models with donor as a random intercept, age was associated with failure strain (−1.9% per year, 95% CI −3.1 to −0.7; p = 0.003) and, more weakly, with strain energy density (−2.7% per year, 95% CI −4.8 to −0.6; p = 0.012), whereas no association was found with strength. Body weight was not associated with any parameter after accounting for clustering within donors (p ≥ 0.34). Conclusions: Donor age was associated with reduced failure strain and strain energy density without a detectable change in ultimate tensile strength. These data provide age-stratified reference values for validating constitutive models and for designing age-specific bioprosthetic and tissue-engineered heart valves.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Mechanical Properties of Native Human Aortic Valve Leaflets Under Uniaxial Tension: Associations with Age, Body Weight, and Cardiovascular Risk Factors — Science Skim