A Comparison of Convolutional, Transformer, and State-Space U-Shaped Pipelines for Neuronal Soma Instance Segmentation in Label-Free 3D Microscopy.
Seda Bayat Toksöz, Gültekin Işık, Gökhan Şahin, Erdal Akin
Department of Computer Engineering, Faculty of Engineering, Iğdır University, 76000 Iğdır, Türkiye. · Copernicus Institute of Sustainable Development, Utrecht University, Princetonlaan 8A, 3584 CB Utrecht, The Netherlands.
Key points
From the paper's conclusion- We compared seven U-shaped semantic-to-instance pipelines (3D U-Net, nnU-Net v2, SwinUNETR, 3D TransUNet, U-Mamba, Swin-UMamba-3D, and an exploratory MedMamba-UNet) on 240 public volumes of six rat, mouse, and human species–modality subsets, using the released partition.
Abstract
Instance segmentation of neuronal somata in label-free three-dimensional (3D) microscopy is challenging because of low contrast, crowding, and species- and modality-dependent appearance. We compared seven U-shaped semantic-to-instance pipelines (3D U-Net, nnU-Net v2, SwinUNETR, 3D TransUNet, U-Mamba, Swin-UMamba-3D, and an exploratory MedMamba-UNet) on 240 public volumes of six rat, mouse, and human species-modality subsets, using the released partition. Models were trained for 25,000 steps with three seeds, post-processing was selected on source-domain validation volumes, and native-grid predictions were scored with Dice, object-level F1, panoptic quality (PQ), and error categories. In-domain, nnU-Net v2 (Dice 0.672 ± 0.001, mean ± SD over seeds) and Swin-UMamba-3D (0.640 ± 0.006) ranked highest, and the six other pipelines scored lower than nnU-Net v2 in Holm-corrected volume-level tests of Dice and F1@0.5 (Hodges-Lehmann Dice differences -0.032 to -0.092). Compared with target-matched in-domain results, Dice decreased by 0.037-0.067 after human-held-out species transfer and by 0.139-0.243 after oblique-to-DGC modality transfer, with all unadjusted confidence intervals excluding zero. PQ (0.253-0.384) remained well below Dice, and missed and spurious somata dominated the errors, so individual soma recovery should be evaluated alongside voxel overlap. Because test volumes informed protocol development and biological source identifiers are unavailable, these comparisons are exploratory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DQIRMask: Dual-quality and instance-relation mask learning for fluorescent neuronal cell instance segmentationPhysica Scripta · 2026
- MambaSplit: Severity-Robust and Inference-Efficient Semantic Unmixing of Fluorescence Microscopy Image DataarXiv · 2026
- Segment Anything for Microscopy 2bioRxiv · 2026
- MitoEM 2.0: A Benchmark for Challenging 3D Mitochondria Instance Segmentation from EM Images.Scientific data · 2026
- Automatic Generation of Expert-Level Neuron Segmentation Masks from Fluorescence Microscopy Images for Non-Invasive Deep Learning Analysis of Phase-Contrast ImagesarXiv · 2026
- SubCellSeg: A generalist model for subcellular structure segmentation in 3D fluorescence microscopybioRxiv · 2026