Explainable Machine Learning for Dataset-Defined Digital Eye Strain Risk Categories: Comparative Evaluation and Sensitivity Analysis.
İrem Şenyer Yapıcı, Rukiye Uzun Arslan, Tuğba Özge Onur
Department of Computer Engineering, Zonguldak Bulent Ecevit University, Zonguldak 67100, Türkiye. · Department of Electrical and Electronics Engineering, Zonguldak Bulent Ecevit University, Zonguldak 67100, Türkiye.
Key points
From the paper's conclusion- The reported metrics quantify agreement with dataset-defined labels, not clinical diagnostic accuracy or the ability to predict future DES risk.
Abstract
Background/Objectives: This study compared eight machine-learning classifiers for three dataset-defined digital eye strain (DES) categories and examined the robustness and interpretation of their predictions. Methods: A publicly available dataset containing 800 observations and 11 nonconstant predictors was analyzed using training-only preprocessing, repeated stratified cross-validation, randomized hyperparameter optimization, and an 80:20 stratified train-test split. Additional analyses included nested cross-validation of support vector machine (SVM) and logistic regression (LR), feature ablation, probability calibration, and SHAP-based interpretation. Results: SVM achieved the highest mean repeated-CV macro-F1 (0.9861). On the held-out test set, SVM achieved 0.9625 accuracy and 0.9636 macro-F1, while LR achieved 0.9688 and 0.9714, respectively. Nested-CV macro-F1 values were similar for SVM (0.9777) and LR (0.9768). Excluding symptom-related predictors reduced test macro-F1 to 0.5141 (SVM) and 0.4902 (LR); additionally, excluding daily screen time reduced these values to 0.3714 and 0.3724. Multiclass Brier scores were 0.0506 for SVM and 0.0456 for LR. Screen time and ocular symptoms also contributed prominently to SHAP explanations. Conclusions: Classification performance depended strongly on symptom and screen-exposure variables. The reported metrics quantify agreement with dataset-defined labels, not clinical diagnostic accuracy or the ability to predict future DES risk. The label-generation criteria are undocumented, supporting clinical gold-standard evidence is unavailable, and potential overlap between predictors and label-generation criteria cannot be excluded. Without validation against independently established clinical outcomes and in external populations, these findings remain dataset-specific classification results and do not establish real-world clinical risk-prediction capability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Interpretable machine learning for self-reported reduced uncorrected visual acuity in school students.Frontiers in public health · 2026
- A Unified Flexible Large Polysomnography Model for Sleep Staging and Downstream Clinical ScreeningmedRxiv · 2026
- Assessment of Visual Fatigue Caused by Eye-Controlled Interaction Based on Task Performance and Pupillary Response with GBDT-LR.Sensors (Basel, Switzerland) · 2026
- Diagnostic Performance of Multimodal Artificial Intelligence in Differentiating Ocular Surface Squamous Neoplasia from Benign Lesions: A Retrospective Diagnostic Accuracy Study.Diagnostics (Basel, Switzerland) · 2026
- Interpretable EOG-based gaze classification using tree-based models: A SHAP and LIME analysis.PloS one · 2026
- Machine learning-based multiclass classification of cognitive decline using ACE-III assessment data: a comparative study with SHAP explainabilityScientific Reports · 2026