Bioengineering (Basel, Switzerland)

Wearable Inertial Phenotyping of Freezing of Gait in Parkinson's Disease: Biomechanical Signatures, Subject-Independent Classification, and Clinical Associations.

Augusto Ielo, Lilla Bonanno, Angelo Quartarone, Serena Dattola

IRCCS Centro Neurolesi Bonino-Pulejo, S.S. 113 Via Palermo, C. da Casazza, 98124 Messina, Italy.

Key points

From the paper's conclusion
  • Wearable inertial signals therefore showed clinically interpretable differences among FoG manifestations, while finer phenotype discrimination remained heterogeneous and requires external validation in independent cohorts.

Abstract

Freezing of gait (FoG) in Parkinson's disease is clinically heterogeneous, yet wearable-sensor studies predominantly focus on binary FoG detection. We investigated whether right-ankle inertial signals can characterize clinically meaningful FoG manifestations within a three-stage conditional framework. Accelerometer and gyroscope data from 22 participants in the FoG-STAR dataset were segmented into 1 s windows. Three subject-independent classification stages were evaluated separately: locomotor non-FoG versus FoG, kinetic versus akinetic FoG, and shuffling versus trembling. Nine interpretable biomechanical features were compared with Logistic Regression, RBF-SVM, Random Forest, and a raw temporal 1D-CNN using frozen participant-independent partitions. The CNN yielded a mean Stage-1 balanced accuracy (0.877 ± 0.034), whereas for Stage-2 kinetic-akinetic discrimination, Logistic Regression and the CNN yielded mean balanced accuracies of 0.730 ± 0.044 and 0.727 ± 0.065, respectively. Stage-3 performance was lower and more variable (Logistic Regression, 0.666 ± 0.133). Nested leave-one-subject-out analysis restricted to mixed-phenotype participants further highlighted subject-level heterogeneity. Kinetic FoG showed greater residual movement amplitude and movement-rate characteristics than akinesia. Protocol-observed locomotor FoG burden was positively associated with FoG-Q (ρ=0.536) and MDS-UPDRS III (ρ=0.785). Wearable inertial signals therefore showed clinically interpretable differences among FoG manifestations, while finer phenotype discrimination remained heterogeneous and requires external validation in independent cohorts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Wearable Inertial Phenotyping of Freezing of Gait in Parkinson's Disease: Biomechanical Signatures, Subject-Independent Classification, and Clinical Associations — Science Skim