DCD-VMUNet: A Dynamic Multi-Scale and Geometry-Aware Network for Coronary Vessel and Stenosis Segmentation in X-Ray Angiography.
Youzhuo Quan, Huaizhi Yue, Xiangyang Ma, Kun Liu
Department of Cardiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China. · School of Information Engineering, Chang'an University, Xi'an 710064, China.
Key points
From the paper's conclusion- These results indicate that DCD-VMUNet improves coronary vessel delineation and pixel-level stenosis localization, supporting automated coronary angiographic assessment.
Abstract
Accurate segmentation of coronary vessels and stenotic regions in X-ray coronary angiography remains challenging because of low vessel-to-background contrast, vessel overlap, thin branches, and the small, ambiguous appearance of stenotic lesions. In this study, we propose DCD-VMUNet, a structure-aware framework for automated coronary vessel and stenosis segmentation. Built on VM-UNet, the model incorporates a dynamic multi-scale kernel module, a centerline head, and a direction head. The dynamic module adaptively integrates fine boundary details with broader contextual cues, while the auxiliary heads introduce geometric supervision to enhance structural continuity and orientation awareness. DCD-VMUNet was independently trained and evaluated for binary vessel and stenosis segmentation on the ARCADE dataset. It was compared with YOLOv11-X, DeepLab v3+, UNet, UNet++, TransUNet, MALUNet, and VM-UNet using pixel-wise metrics and, for vessel segmentation, the centerline-aware clDice metric. For vessel segmentation, DCD-VMUNet achieved the best performance, with IoU, precision, recall, and F1-score of 0.6838, 0.8418, 0.7846, and 0.8122. For stenosis segmentation, it also ranked first across all metrics, reaching 0.4042, 0.5826, 0.5688, and 0.5757, respectively. Ablation studies confirmed the complementary effects of multi-scale feature extraction and geometric supervision. Additional evaluation on the independent ICA dataset further supported the vessel segmentation performance of DCD-VMUNet beyond the ARCADE benchmark. These results indicate that DCD-VMUNet improves coronary vessel delineation and pixel-level stenosis localization, supporting automated coronary angiographic assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray AngiographyarXiv · 2026
- VMamba-QAG-net: a five-stage pipeline for SYNTAX score computation and decision support in interventional cardiology using X-ray angiography.Frontiers in artificial intelligence · 2026
- CC-GAN: Coronary Artery 3D Reconstruction From Two X-Ray Views With Mamba-Based Topology-Aware Generator and Dual-Domain Discriminator.IEEE journal of biomedical and health informatics · 2026
- CASSFormer: A Lightweight CNN-Transformer Hybrid Network for Real-Time Coronary Artery Stenosis Detection and Localization.Journal of imaging informatics in medicine · 2026
- Multi-view and multi-frame voting-based stenosis detection and quantification in X-ray coronary angiography.Journal of medical imaging (Bellingham, Wash.) · 2026
- DMNet-E: Enhanced dual-segmentation multi-decoder network strategy for advancing IVOCT plaque segmentation.Artificial intelligence in medicine · 2026