Evaluation of the Force System Acting Within an Orthodontic Appliance.
Amelia Smaranda Roșianu, Dragoș Laurențiu Popa, Gabriel Buciu, Stelian-Mihai-Sever Petrescu
Department of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania. · Department of Automotive, Transportation and Industrial Engineering, Faculty of Mechanics, University of Craiova, 200478 Craiova, Romania.
Key points
From the paper's conclusion- Patient-specific three-dimensional reconstruction combined with a local analytical beam approximation provides a framework for estimating geometry-dependent elastic force components within an orthodontic appliance. The calculated values should be interpreted as equivalent local force estimates derived from the reconstructed geometry and not as a complete three-dimensional force-moment system.
Abstract
BACKGROUND: Implant-prosthetic rehabilitation of single-tooth edentulism often requires orthodontic reshaping of the potential implant-prosthetic space because its dimensions change due to the migration of adjacent teeth. In this context, it is very important to understand the force system generated by orthodontic arches in order to control tooth movement and to achieve, at the end of orthodontic treatment, the correct dimensions of the potential implant-prosthetic space for dental implant placement. MATERIALS AND METHODS: The study was based on CBCT images acquired from a 25-year-old female patient with maxillary and mandibular lateral edentulism. The images were processed using InVesalius and Geomagic to obtain a patient-specific three-dimensional reconstruction of the dento-maxillary structures. Orthodontic brackets, adhesive components, and round-section nickel-titanium archwires were subsequently modeled and positioned within a common three-dimensional coordinate system. The reconstructed geometry was used to extract local geometric parameters of the archwire. These parameters were subsequently introduced into a local equivalent Euler-Bernoulli beam formulation to estimate elastic force components and transverse reactions associated with the bracket-related points. RESULTS: The study revealed an uneven distribution of forces along the orthodontic arches. For the upper arch, the elastic force values ranged from 0.044 to 0.383 N, and for the lower arch, from 0.050 to 0.308 N. The calculated reactions at the bracket components also varied depending on the orthodontic archwire geometry and the position of the support points. CONCLUSIONS: Patient-specific three-dimensional reconstruction combined with a local analytical beam approximation provides a framework for estimating geometry-dependent elastic force components within an orthodontic appliance. The calculated values should be interpreted as equivalent local force estimates derived from the reconstructed geometry and not as a complete three-dimensional force-moment system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Coupled FE Modeling of Superelastic NiTi Arch Wire and Bone Remodeling to Simulate 3D Orthodontic Tooth Movement During Leveling Phase.International journal for numerical methods in biomedical engineering · 2026
- Biomechanical Assessment of a Novel Self-Ligating Orthodontic Bracket Using Finite Element Analysis: The LUMACA System.Dentistry journal · 2026
- Combined effects and weight analysis of factors affecting initial maxillary central incisor retraction: a three-dimensional finite element study.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical effects of six reverse curve of Spee NiTi archwires: A three-dimensional finite element study.International orthodontics · 2026
- Bite Force Analysis Using Numerical Simulation with Different Prosthesis Anchorages.Biomimetics (Basel, Switzerland) · 2026
- Mechanical in-silico modeling of orthodontic tooth movement: A review of the boundary value problemMathematics and Mechanics of Solids · 2025