Finite Element Analysis of Ultra-Short, Extra-Short, and Conventional Dental Implants in Fibula Free Flap Mandibular Reconstruction.
Mario Ceddia, Luciano Lamberti, Bartolomeo Trentadue
Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy.
Key points
From the paper's conclusion- Within the limitations of this study and under the simulated immediate postoperative loading condition, shorter implants, particularly 5 mm implants, showed a favorable biomechanical response.
Abstract
UNLABELLED: Dental rehabilitation of fibula free flap mandibular reconstructions can be limited by the reduced vertical bone height available for implant placement. This study evaluated the biomechanical influence of ultra-short, extra-short, and conventional implants in a reconstructed fibula. METHODS: A patient-specific finite element model of a fibula-reconstructed mandible was developed. Three splinted implants with a diameter of 4 mm and lengths of 3, 5, or 12 mm were compared under postoperative unilateral molar loading. Von Mises stresses were evaluated in the implants, fibula, residual mandible, and fixation plates, while equivalent elastic strain was assessed in peri-implant bone. RESULTS: Implant length had minimal influence on implant stress (36.8-37.1 MPa) and fibular cortical bone stress (52.5-53.1 MPa). The 5 mm implants produced the lowest peri-implant strains and the lowest posterior reconstruction-plate stress (71.3 MPa), compared with 75.4 MPa for 3 mm and 107.8 MPa for 12 mm implants. The 12 mm implants generated greater apical strain concentrations, exceeding the adopted mechanobiological threshold around the central and mesial implants. CONCLUSIONS: Within the limitations of this study and under the simulated immediate postoperative loading condition, shorter implants, particularly 5 mm implants, showed a favorable biomechanical response.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of subperiosteal, short, and standard endosseous implants in the severely atrophic edentulous mandible: a three-dimensional finite element stress analysis study.BMC oral health · 2026
- Mechanobiological modeling of bone healing in mandibular reconstruction: a comparative study of fixation strategiesComputer Methods in Biomechanics & Biomedical Engineering · 2026
- Biomechanical Comparative Evaluation of the Atrophic Edentulous Mandible Using All-on-4, All-on-5 and All-on-6 Concepts: A Finite Element Analysis.Dentistry journal · 2026
- Analysis of stress distribution around conventional and basal dental implants in the posterior mandible: A finite element study.Journal of Indian Society of Periodontology · 2026
- Finite element evaluation of the biomechanical feasibility of a multi-shield socket shield technique for a vertically fractured maxillary central incisor.Medical engineering & physics · 2026
- Biomechanical Comparison of All-on-Four and Interforaminal All-on-Six Concepts Using Titanium and Ti-Zr (Roxolid®): A Nonlinear Finite Element Study.Journal of stomatology, oral and maxillofacial surgery · 2026