Displacement Forces in Different Proximal Landing Zones for Thoracic Endovascular Aortic Repair: Towards Patient-Specific Assessment.
Michele Conti, Valentina Ceserani, Irene Baroni, Daniele Bianchi, Nicoletta Curcio, Alessandro Reali, Ferdinando Auricchio, Francesco Secchi,
Department of Civil Engineering and Architecture, University of Pavia, 27100 Pavia, Italy. · Clinical Research Service, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Italy.
Key points
From the paper's conclusion- We found that zones 0 and 3 exhibited a high magnitude of displacement forces.
Abstract
Thoracic endovascular aortic repair (TEVAR) is one of the main treatments, together with open aortic repair, for thoracic aortic aneurysm. This procedure is associated with low procedural morbidity and mortality and provides satisfactory mid-term results. However, identifying the optimal location for device deployment before the operation remains essential. In previous studies, computer simulations were used to examine the hemodynamic stress linked to different areas of the arch, pinpointing regions unsuitable for TEVAR delivery. Computational fluid dynamics (CFD) simulations suggest that zone 3 poses the most challenges for delivering endograft in type III arches, as it is considered a hostile region from biomechanical and hemodynamic perspectives. Morphologically, type III aortic arch shows a more pronounced curvature and a lower position of the arch, resulting in increased separation between the ascending and descending aorta. However, these studies utilized 3D geometrical models reconstructed from computed tomography angiography scans. Still, the flow boundary conditions were based on existing data rather than the specific hemodynamic characteristics of the patient. To bridge this gap, the present study uses MRI flow wave data to compute displacement forces (DFs) for each proximal landing zone. We found that zones 0 and 3 exhibited a high magnitude of displacement forces. Still, only zone 3 was identified as the most hemodynamically stressed area when the force was normalized for the lumen area. Furthermore, there was a significant discontinuity in the upward components of DFs between zone 2 and zone 3. The patient-specific assessment of displacement forces enabled us to identify suboptimal areas for TEVAR delivery, suggesting that personalized computer simulations could greatly enhance preoperative planning for TEVAR procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predicting Post-TEVAR Endoleaks: A Pre-operative Hemodynamic Risk Factor from Patient-Specific Fluid-Structure Interaction Simulations.Annals of biomedical engineering · 2026
- Assessing Hemodynamic Impact of Tissue-Engineered Vascular Graft Displacement: Combining Postoperative In Vivo Results and Computational Modeling to Improve Surgical Planning.Annals of biomedical engineering · 2026
- Zone 2 Versus Zone 3: Thoracic Endovascular Aortic Repair's Tough Choice in Acute Type B Aortic Dissection: Systematic Review and Meta-Analysis.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- Prediction of Thoracic Endovascular Aortic Repair Intervention: Proof of Concept using Digital Twin TechnologyEuropean Journal of Vascular and Endovascular Surgery · 2026
- Dedicated Single-Branch Platforms for Totally Endovascular Zone 2 TEVAR with LSA Revascularization: A Comparison of Castor/Cratos and Gore TAG Thoracic Branch EndoprosthesisJournal of Clinical Medicine · 2026
- Thoracic Branched Endografts in Acute Aortic Syndromes: Expanding Indications, but at What Cost?Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026