MaxI-Net: A 3D AI Framework for CBCT-Based Maxillofacial Defect Reconstruction and Patient-Specific Implant Generation with Biomechanical Validation
Mamta Juneja, Maanya Kharbanda, Nitin Pandey, Agrima Sudhir, Aditya Poddar, Harleen Kaur, Prashant Prakash, Manojkumar Jaiswal,
Panjab University · Post Graduate Institute of Medical Education and Research
Key points
From the paper's conclusion- Biomechanical validation using a finite element analysis (FEA) of polyether–ether–ketone (PEEK) implants (~26.53 g) showed 41% stress reduction under physiological loads (100–400 N), predicting a ~9.2-year lifespan.
Abstract
Maxillofacial defects impair facial aesthetics and oral function, arising from trauma, tumor resection, or congenital anomalies; however, reconstruction using Computer-Aided Design (CAD) and autologous grafts remains complex and time-intensive, and is associated with donor-site morbidity. Although deep learning (DL) has advanced automated reconstruction, existing models often address isolated tasks, lack integrated multi-scale feature learning, and rely on small datasets. This study proposes the Maxillofacial Implant-generation Network (MaxI-Net), a fast, resource-efficient three-dimensional DL framework for end-to-end maxillofacial defect reconstruction and patient-specific implant generation, with a completion step of cavity filling within the assembly. The model employs a 3D encoder–bottleneck-decoder architecture integrating hybrid dilated convolutions, residual connections, squeeze-and-excitation (SE) blocks, and 3D Convolutional Block Attention Modules (CBAM) with multi-scale feature fusion. It was trained on 921 Cone Beam-Computed Tomography (CBCT) scans, augmented to 11,973 maxillary defect pairs, using Dice loss and Adam optimisation with Automatic Mixed Precision, and benchmarked against UNet, UNETR, SegResNet, and SwinUNETR. MaxI-Net achieved the following: superior Dice Similarity Coefficient (DSC) = 0.778; 95th percentile Hausdorff Distance (HD95) = 3.453 mm; DSC Standard Deviation (SD) = 0.094; 95% confidence interval (CI) for mean DSC: 0.775–0.782). It was statistically validated against all competing architectures via pairwise Wilcoxon signed-rank tests, with significant DSC improvements confirmed across all comparators (p < 0.001) and rank-biserial effect sizes ranging from r = 0.250 against the closest competitor SegResNet* with high efficiency (0.06 s/volume; 9.6 min/epoch). Internal cavity filling of the generated implants was performed as a brief manual post-processing step in Autodesk Fusion 360 prior to biomechanical validation. Biomechanical validation using a finite element analysis (FEA) of polyether–ether–ketone (PEEK) implants (~26.53 g) showed 41% stress reduction under physiological loads (100–400 N), predicting a ~9.2-year lifespan.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-Driven CBCT Analysis for Surgical Decision-Making and Mucosal Damage Prediction in Sinus Lift Surgery for patients with low RBHInternational Dental Journal · 2025
- AI-driven reconstruction of maxillary complete denture bases: a clinical feasibility study.Clinical oral investigations · 2026
- Accuracy and reliability of 3D cephalometric landmark detection with deep learningEuropean journal of medical research · 2025
- MedReShaper: mesh-based AI for 3D anatomical shape completion in orbital fracture reconstruction with controlled technical validation.Medical image analysis · 2026
- Automated Multi-class Segmentation of Mandibular Odontogenic Cysts and the Mandibular Canal on CBCT Images Using a Hybrid Deep Learning Framework.Journal of imaging informatics in medicine · 2026
- Evaluation of Maxillary Sinus Membrane Morphology Using a Novel Hybrid CNN-ViT-Based Deep Learning Model: An Automated Classification StudyDiagnostics · 2026