Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework
Abinaya J., Anitha Suseelan
Key points
From the paper's conclusion- This study addresses that gap by combining regression-based importance weighting with framework-level and occupant-level Importance-Performance Analysis (IPA), drawing on post-occupancy surveys of 981 occupants across two GRIHA-certified higher educational buildings in South India (3-Star, n = 208; 4-Star, n = 773).
Abstract
India’s Green Building Rating System (GRIHA) has progressively expanded its Indoor Environmental Quality (IEQ) provisions, yet these remain based on design-stage documentation rather than empirically measured occupant priorities, particularly for warm-humid higher educational buildings. This study addresses that gap by combining regression-based importance weighting with framework-level and occupant-level Importance-Performance Analysis (IPA), drawing on post-occupancy surveys of 981 occupants across two GRIHA-certified higher educational buildings in South India (3-Star, n = 208; 4-Star, n = 773). Multiple regression identified Acoustic Comfort as the strongest predictor of perceived productivity (beta = 0.514, p < 0.001), followed by Spatial Comfort (beta = 0.198, p < 0.001); Indoor Air Quality was not a significant predictor (beta = 0.024, p = 0.298), with the model explaining 76.3% of variance (R2 = 0.763). Framework-level IPA placed Acoustic and Spatial Comfort in the under-invested quadrant (high regression beta, low GRIHA allocation), while Indoor Air Quality, which receives 54% of GRIHA’s IEQ points, fell in the over-invested quadrant (low beta, high allocation). Occupant-level IPA rated Acoustic Comfort as the most important domain and identified Spatial Comfort as the only domain in the Concentrate Here quadrant, and an independently derived Bayesian estimate of domain weights ranked Acoustic Comfort highest and Indoor Air Quality lowest, in agreement with the regression. Based on these findings, a recalibration is proposed: acoustic weighting increased from 2 to 5 points (partly mandatory), a new 3-point Spatial Comfort criterion introduced, IAQ allocation reduced from 7 to 4 points, with credit routes adapted to ventilation mode, and a voluntary 2-point post-occupancy evaluation bonus added, broadly consistent with LEED v5’s parallel shift toward occupant-experience criteria.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Human Environmental Quality: Testing the Incremental Validity of Sensory and Restorative DomainsInternational Journal of Environmental Research and Public Health · 2026
- Occupant centric indoor environmental quality assessment within institutional settingsSmart and Sustainable Built Environment · 2026
- Mapping Domain-Specific IEQ Exposure-Outcome Pathways: A Systematic Review and Standardized Research Framework of Objective Human Health ResponsesBuildings · 2026
- A formalism for a general theory of subjective multi-domain indoor-environmental quality perceptionFrontiers in Built Environment · 2026
- Modeling indoor environmental quality impacts on student comfort and learning in hot-arid educational environmentSmart and Sustainable Built Environment · 2025
- Occupant Perceptions of Indoor Air Quality Determinants, Monitoring Awareness and Mitigation Priorities in Near-Road Purpose-Built Student Accommodation: An Exploratory UK Case StudyJournal of Sustainable Development · 2026