Static and Dynamic Responses of a Valley-Type Ash Storage Dam After Intense Rainfall

Yumeng Zhang, Jie Zhao, Tongkun Ding, Hongchun Xia

Key points

From the paper's conclusion
  • These results indicate distinct spatial patterns of sliding stability and local seismic response for the modeled dam.

Abstract

This study examined the effects of post-rainfall hydrological conditions on the stability and seismic response of a valley-type ash storage dam in Liaoning, China. Laboratory tests and field water-level measurements were combined with sequential seepage, static stability, and dynamic analyses. The mean absolute error between the calculated and measured water levels at four monitoring points was 0.565 m. Dynamic triaxial tests revealed a decrease in the shear modulus ratio and an increase in the damping ratio with increasing effective shear strain. After receiving a uniform rainfall of 96 mm/d for 48 h, the dry beach length decreased from 100 to 50 m; for the same cumulative rainfall and duration, a late-peaking pattern reduced it to 30 m. The static factor of safety of the starter dam decreased by approximately 20%. At input amplitudes of 0.125 and 0.200 g, the relative acceleration and total displacement increased after rainfall. The largest local responses were observed near the crest and upper slope, and the starter dam had a lower factor of safety. These results indicate distinct spatial patterns of sliding stability and local seismic response for the modeled dam.