Bearing Performance of a Precast Circular Pipe-Jacking Working Shaft: Full-Scale Experimental and Numerical Investigation
Xingqi Zhang, Zhengguang Hu, Gan Qin, Huayan Yao, Li Yuan, Fan Yang
Key points
From the paper's conclusion- The results indicate a strongly localized soil disturbance mainly outside the reaction segment, with the core loaded zone being the reaction segment and its adjacent cutting-edge and standard-ring segments.
Abstract
With the growing use of precast circular pipe-jacking working shafts in urban drainage projects, their bearing performance under jacking reaction forces remains insufficiently understood, limiting reliable structural design. A full-scale field experiment and a detailed numerical simulation were carried out on the No. 16 precast circular pipe-jacking working shaft of the Xiyou Road drainage pipeline project in Hefei; gauges monitored soil pressure, concrete stress, and bolt axial force of the reaction segment and adjacent segments as the jacking force was raised to the structural limit. The numerical model included shaft–soil contact and segment–bolt connections to capture the mechanical responses. The results indicate a strongly localized soil disturbance mainly outside the reaction segment, with the core loaded zone being the reaction segment and its adjacent cutting-edge and standard-ring segments. Tensile stress was concentrated on the inner face of the cutting-edge ring and at its segment joints, and at 3000 kN the principal tensile stress approached the C40 concrete tensile strength. Only the bolts around the reaction segment were clearly tensioned, with stresses far below capacity. The experiment showed no cracking at the maximum measured force of 2600 kN, and a nominal cracking-initiation capacity of about 3000 kN was estimated numerically by extrapolation beyond the measured range. Quantitatively, at the maximum measured jacking force of 2600 kN the soil pressure outside the reaction segment increased from about −0.05 MPa to between −0.15 and −0.17 MPa, while that at the adjacent segment remained close to −0.04 MPa; the measured circumferential and vertical concrete stress increments did not exceed about 0.70 and 0.55 MPa in magnitude, respectively; and the bolt axial-force increments were small, with envelope maxima of about 14 kN for the vertical bolts and about 40 kN for the circumferential bolts over the full loading range. At 3000 kN, the computed maximum principal tensile stress at the cutting-edge-ring joints reached 2.35 MPa, close to the 2.39 MPa axial tensile strength of C40 concrete, whereas the maximum bolt stress was 294.55 MPa against the 800 MPa strength of 8.8-grade bolts. These findings provide a reference for the structural design and safety control of such working shafts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prediction of jacking force in circular press-in caisson in clayCanadian Geotechnical Journal · 2025
- Calculation Model for Jacking Force of Large-Diameter Reinforced Concrete Pipe Jacking Considering Slurry Lubrication Evolution and Effective Contact Pressure Around the PipeBuildings · 2026
- Investigation of construction settlement for super-long bidirectional circular pipe jacking - launching shaft structureJournal of Engineering and Applied Science · 2026
- Experimental and Numerical Investigation of the Dynamic Evolution and Interface Friction Characteristics of Pipe Jacking Thrust in Sandstone FormationsApplied Sciences · 2026
- Analysis of construction response for mechanized construction of metro connecting passages.PloS one · 2026
- Equivalent Cross-Sectional Area of Micropile Groups Under Different Surrounding Rock-Mass StrengthsCivilEng · 2026