Experimental Characterization of Laser-Generated Ultrasound Using an Er:Glass Laser and Optical Microphone
Caspar Wasle, Florian Heilemann, Rebecca Rodeck, Gerko Wende
Key points
From the paper's conclusion- The results provide quantitative baseline data on the acoustic response of the Er:glass laser–microphone system and demonstrate its feasibility for compact, eye-safe, contactless ultrasonic measurements within the investigated parameter range.
Abstract
This study investigates a fully contactless laser-ultrasound setup combining a compact erbium-glass (Er:glass) laser operating at an eye-safe wavelength of 1540 nm and an optical microphone. The objective is to provide a baseline experimental characterization of this configuration under controlled conditions. Experiments are conducted on aluminum plates of varying thickness in both through-transmission (forward detection) and single-sided (backward detection) measurement configurations, using laser pulse energies between 0.9 mJ and 10 mJ. Measurable ultrasonic signals are obtained across all tested conditions, with signal amplitudes exceeding the noise floor even at the lowest pulse energy. Both guided-wave components and thickness-resonance frequencies are observed, with measured resonance frequencies in reasonable agreement with theoretical expectations. Parametric studies show systematic dependencies of signal amplitude, reported in absolute sound-pressure units, on laser energy, spot size, and microphone standoff distance. The airborne radiation characteristics of the generated ultrasound are analyzed to determine suitable sensor placement for different wave components. In single-sided configurations, disturbance mechanisms including direct optical interference and air-coupled acoustic waves are identified. The use of a shielding wall with minimal air gap is shown to reduce airborne disturbance components. The results provide quantitative baseline data on the acoustic response of the Er:glass laser–microphone system and demonstrate its feasibility for compact, eye-safe, contactless ultrasonic measurements within the investigated parameter range.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved laser Ultrasonics NDT through simultaneous quasi-monochromatic and pulsed Rayleigh waves generation.Ultrasonics · 2026
- Visualizing Laser Ultrasound Wave Propagation Using a Wollaston-Based Stroboscopic Schlieren Interferometer.IEEE transactions on ultrasonics · 2026
- Frequency-selective photoacoustic lamb wave generation using slit-patterned CSNP-PDMS transmitters with fully non-contact characterization.Ultrasonics · 2026
- Integrated optomechanical ultrasonic sensors with nano-Pascal-level sensitivityLight Science & Applications · 2026
- Laser Ultrasound Nondestructive Testing in Aerospace Materials: Principles and ApplicationsMicrowave and Optical Technology Letters · 2026
- High-power pulsed-laser ablation of aluminum alloy: Simulation model and experimental validation.PloS one · 2026