Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot
Yuepeng Zhang, Shaohong Wang, Guangzhong Cao, Xueli Zhu, Bo Gao, Linzhong Xia
Key points
From the paper's conclusion- The results show that the proposed isolator achieves pronounced low-frequency acceleration suppression at the cost of a small displacement increase, and the offset compensation module maintains the QZS operating point under ±90° tilting.
Abstract
To isolate the low-frequency vibration of the ground-penetrating radar (GPR) payload mounted at the end of a manipulator on a tunnel diagnostic vehicle, a two degree-of-freedom (DOF) quasi-zero-stiffness (QZS) vibration isolator is proposed. It consists of two identical 1-DOF units stacked vertically and arranged orthogonally in the horizontal plane. Each unit integrates linear extension springs, a rhombus negative-stiffness mechanism, an X-shaped positive-stiffness mechanism, a guide mechanism, and an offset compensation module. A static/dynamic model is established, the key parameters are optimized by a genetic algorithm, and the critical support structures are topologically optimized with a mass reduction of more than 50%. The optimized dimensionless stiffness at the static equilibrium is 0.2204, and the onset isolation frequency is about 0.6 Hz; the displacement transmissibility is below 0.5 above 1 Hz. Under pulse excitation, the peak-to-peak acceleration and displacement are reduced to approximately 6.2% and 28.5% of those of a linear isolator, respectively. Under 1.5 Hz harmonic excitation, the steady-state absolute acceleration and displacement amplitudes are reduced by about 41% and 48%, respectively, while the dynamic deflection increases. In vehicle–arm co-simulations under three pulse cases, the peak-to-peak displacement and acceleration are reduced by 48.59–74.38% and 84.73–93.44%, respectively. Under D-grade random road excitation, the peak-to-peak acceleration and acceleration RMS are reduced by 53.34% and 77.25%, respectively; the peak-to-peak displacement is reduced by 12.63%, whereas the peak absolute displacement and displacement RMS increase slightly by 1.21% and 3.62%. The maximum dynamic displacement remains within the designed ±50 mm stroke. The results show that the proposed isolator achieves pronounced low-frequency acceleration suppression at the cost of a small displacement increase, and the offset compensation module maintains the QZS operating point under ±90° tilting. These findings provide a passive isolation solution for manipulator-mounted precision equipment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quasi-zero-stiffness vibration isolation: A comprehensive review of design principles and engineering applicationsInternational Journal of Non-Linear Mechanics · 2026
- Quasi-zero stiffness vibration isolator with variable stiffness and variable damping for ultralow-frequency vibration under variable mass loadChinese Journal of Mechanical Engineering · 2026
- Accelerated design of curved-beam-based torsional isolator with quasi-zero stiffnessEngineering Structures · 2026
- On a broadband vibration isolator with tunable stiffness: from quasi-zero-stiffness to zero-stiffness behaviorApplied Mathematics and Mechanics · 2026
- Design and analysis of a quasi-zero stiffness vibration isolation system with load adaptabilityResults in Engineering · 2025
- A Novel Bioinspired Quasi-Zero Stiffness Ultra-Low-Frequency Vibration Isolation System for Ambulance Stretchers: Insights from Avian Lower LimbsIEEE Transactions on Industrial Electronics · 2025