IoT-Enabled Volunteer Practitioner Framework for Pre-Hospital Emergency Response: Extended TAM-Based Adoption Analysis and Simulation-Based Performance Evaluation in Riyadh
Nawal Almutairi
Key points
From the paper's conclusion- These findings suggest that the proposed framework may facilitate earlier initiation of pre-hospital interventions and could serve as a complementary mechanism to existing emergency response systems.
Abstract
Delays in pre-hospital care continue to undermine the effectiveness of emergency response, particularly in settings where conventional ambulance services cannot reach patients within critical intervention windows. This paper presents an IoT-enabled framework that integrates a mobile application, a smartwatch, and a network of volunteer healthcare practitioners to enable rapid on-site first aid intervention that may enhance pre-hospital emergency response. The system was developed using an Agile methodology with continuous stakeholder engagement to ensure alignment between system requirements and real-world emergency response needs. The framework was evaluated in Riyadh, Saudi Arabia, through two complementary phases. The first phase assessed user-centered aspects among 420 participants, examining usability via the System Usability Scale (SUS) and technology acceptance via an extended Technology Acceptance Model incorporating constructs from Institutional Theory and performance expectancy. The second phase evaluated operational performance using 25 controlled emergency simulation scenarios, measuring emergency alert latency and response time. Results showed a mean SUS score of 78.25, exceeding the commonly accepted benchmark of 68, indicating high perceived usability. Linear regression analyses showed that perceived usefulness, performance expectancy, and coercive and normative pressures were each significantly associated with behavioral intention to adopt the proposed system. Operational evaluation indicated a mean emergency alert latency of 5.40±3.76 s and an 18.45% reduction in mean response time relative to estimated ambulance dispatch, both under controlled simulation conditions. These findings suggest that the proposed framework may facilitate earlier initiation of pre-hospital interventions and could serve as a complementary mechanism to existing emergency response systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- User-Centered Evaluation of an AR Virtual Triage Tag: Responder Perceptions and Performance with Virtual and 'Real' Patient Actors.IEEE transactions on visualization and computer graphics · 2026
- Improved Suction Efficiency and User Satisfaction With a Novel Portable Manual Suction Device: A Simulation-Based Pre-Hospital Study.Inquiry : a journal of medical care organization, provision and financing · 2026
- Artificial Intelligence in Prehospital Tele-Emergency Medicine: A Survey of Acceptance and Attitudes.Healthcare (Basel, Switzerland) · 2026
- A Novel Mobile Health Software Platform to Improve Emergency Medical Systems: 912Rwanda.Research square · 2026
- AEDHunter: Investigating AED Retrieval in the Real World via Gamified Mobile Interaction and SensingProceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · 2026
- RESCUE-AR: Responsive Sensor-Fusion for Civil-Protection and Disaster Response Using Mobile Augmented Reality.Sensors (Basel, Switzerland) · 2026