A Study on the Voltage Resonance to Improve the Operation of the MR Damper-Based Vibration Reduction System with Energy Harvesting
Łukasz Jastrzębski, Bogdan Sapiński
Key points
From the paper's conclusion- Together with the vibration-isolated object, the MRD-VRS constitutes a mechanical system with one degree of freedom (1DOF), which is set in motion by kinematic excitation.
Abstract
This paper deals with a magnetorheological damper-based vibration reduction system (MRD-VRS) with an energy harvesting ability. Together with the vibration-isolated object, the MRD-VRS constitutes a mechanical system with one degree of freedom (1DOF), which is set in motion by kinematic excitation. The authors propose improving the system performance by utilising voltage resonance in its electrical circuit. The originality of the concept involves placing an RLC two-port network between the harvester coil (the electrical energy source) and the MR damper coil (the receiver). This increases the current amplitude selectively, resulting in an increase in the force produced by the MR damper neighbouring the 1DOF mechanical system’s resonance frequency. At the same time, this current is reduced at frequencies significantly higher than the resonance frequency. The intention behind shaping the current in the MR damper coil is to improve the MRD-VRS’s performance, so that it can reduce the vibration-isolated object’s displacement amplitude more effectively across the entire frequency range. The aim of the study is to determine the RLC two-port network parameters that maximise the MR damper coil current at the mechanical resonance frequency of the 1DOF system by exploiting voltage resonance. It should be noted that the resonant frequency of the RLC two-port network differs from the frequency at which the maximum current in the MR damper coil is achieved, since the electrical circuit is branched. The paper considers a mathematical model, the results of numerical simulations and the validation of both the electrical circuit comprising an RLC two-port network and the MRD-VRS under consideration. Analysis of the numerical results determined the resonant frequency and quality factor of the RLC two-port network, achieving the greatest improvement in vibration damping efficiency across the entire range of excitation frequencies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental Analysis and Genetic Algorithm Parameter Identification of a Reduced-order Model for a Single Spring-mass System Coupled to a Magnetorheological Tuned Liquid Column DamperJournal of Vibration Engineering & Technologies · 2026
- A dual-coil energy-coupled actuator with magnetic-flux-path reconstruction and excitation optimization for high-speed on/off valvesSmart Materials and Structures · 2026
- Modeling and Control of a Hybrid Passive/Semi-Active Magnetorheological Recoil Damper with a Pressure-Actuated Stroke-Limiting ValveActuators · 2026
- Rotationally Tunable Permanent Magnet Magnetorheological Damper for Stepless Damping Control: Magnetic Modeling and Experimental ValidationInternational Journal of Structural Stability and Dynamics · 2025
- Electromagnetic Non-Resonant Vibration Energy Harvesters with Linear Magnetic Gear.Micromachines · 2026
- Semi-Active Control of Magnetorheological Elastomer Engine Mounts: Diagnosing the Limits of Transferring Skyhook ControlActuators · 2026