QTANet: Boundary-Aware Deep Learning for Single-Lead QT-Interval Measurement
Sang-Bum Park, Myungeun Lee, Jinwon Heo, Yoo Ri Kim, Hyung-Jeong Yang
Key points
From the paper's conclusion- These findings support boundary-derived QT measurement with jointly reported error and coverage; clinical utility requires further validation.
Abstract
Accurate QT-interval measurement requires reliable identification of QRS onset and T-wave offset. We present QTANet, a single-lead framework that classifies ECG samples as baseline, QRS or T wave and derives QT from the detected landmarks. We used 179 recordings from the Lobachevsky University Electrocardiography Database, with a fixed test set and patient-wise cross-validation, and external evaluation without fine-tuning on the QT Database (QTDB) and 33 clinical recordings. On the expert-annotated QTDB interval subset of 101 recordings, QTANet achieved a mean absolute error of 34.94 ms and measurement coverage of 95.2%, compared with 40.55 ms and 88.2% for the control without attention and 52.41 ms and 68.7% for NeuroKit2. In a separate expert-annotated subset permitting frame-level evaluation, attention increased per-recording T-wave F1 by 0.061, with improvement in 30 of 41 recordings. Attention most consistently reduced T waves misread as QRS complexes. QTANet outperformed an identically trained published U-Net externally at frame level but had higher internal QT error; a larger modern U-Net outperformed QTANet at frame level and in QTDB QT error. Internal interval-level gains were small and clinical results varied across training seeds. These findings support boundary-derived QT measurement with jointly reported error and coverage; clinical utility requires further validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- pedQTNet: A Deep Learning Approach to Estimate Corrected QT Intervals from Multi-Lead Conventional ECG Waveforms in Pediatric PatientsJournal of Medical Systems · 2026
- Teaching an ECG model where to look does not make it more robust to missing leads: a pre-registered comparison of guideline-based attention guidance with random lead maskingmedRxiv · 2026
- Explainable electrocardiogram interpretation using deep learning-based semantic segmentation.European heart journal. Digital health · 2026
- Deep Learning–Based Continuous QT Monitoring to Identify High-Risk Prolongation Events After Class III Antiarrhythmic InitiationCirculation · 2025
- Artificial intelligence-based automated interpretation of images of electrocardiograms: development and multinational validation of ECG-GPTEuropean Heart Journal - Digital Health · 2026
- Multi-Tier Validation of a Single-Lead Wearable ECG Signal-Processing Pipeline: Clinical Comparison and Algorithmic Benchmarking on Public Expert-Annotated Databases.Sensors (Basel, Switzerland) · 2026