Numerical Investigation of the Effects of Temperature-Dependent Permittivity and Space-Charge Transport on the Electric-Field Distribution in the Oil–Paper Insulation of an Oil-Immersed Transformer
Wenrong Si, Heli Ni, Yingying Zhao, Chenzhao Fu, Peng Yuan, Jingyi Shen, Jian Yang
Key points
From the paper's conclusion- The results show that temperature-dependent dielectric parameters increase the maximum electric-field strength in transformer oil from 0.358 to 0.374 kV/mm and decrease that in insulating paper from 0.568 to 0.541 kV/mm, without shifting the major high-field regions.
Abstract
To investigate the effects of the thermal state under rated operation and space-charge transport on the electric-field distribution in oil–paper insulation, a sequentially coupled multiphysics model is developed for a 30 kVA single-phase three-limb oil-immersed transformer. The non-uniform temperature field is mapped onto transformer oil and insulating paper, and electric-field distributions with constant and temperature-dependent dielectric parameters are compared. Short-term charge-transport calculations and initial space-charge sensitivity analysis are also performed under fixed peak-potential boundary conditions. The results show that temperature-dependent dielectric parameters increase the maximum electric-field strength in transformer oil from 0.358 to 0.374 kV/mm and decrease that in insulating paper from 0.568 to 0.541 kV/mm, without shifting the major high-field regions. In Case 3 (under initially charge-neutral conditions), positive and negative space charges accumulate in the oil regions adjacent to the low- and high-voltage winding ends, respectively, while the space-charge density in the middle of the main insulation oil duct remains near zero. Compared with Case 2 (under temperature-dependent dielectric conditions), the maximum field strengths in oil and paper decrease by 2.14% and 24.58%, respectively. For Cases 3–6, from initially charge-neutral to moderate space-charge conditions, maximum-field variations remain within approximately 5%, whereas Case 7 (highest initial positive-charge condition) shows pronounced field enhancement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temperature-Dependent Electric Field Distribution in Current Transformers with Advanced Paper–Liquid Insulation SystemsElectronics · 2026
- Electric Field Distortion and Insulation Response Characteristics of Typical Defects in 35 kV Oil-Impregnated Paper BushingsEnergies · 2026
- Study on electric field distribution and dielectric loss characteristics of insulation gap in dry-type transformer based on finite element methodFrontiers in Electronics · 2026
- High-Frequency Transformer Modeling: Methods, Parameter Extraction and Validation—A ReviewEnergies · 2026
- Thermal-aging-dependent electric-field redistribution and interfacial charge dynamics in oil-pressboard insulation under DC and polarity reversal voltagesJournal of Physics D: Applied Physics · 2026
- Toward Intelligent Power Transformer Diagnostics: From Multi-Source Condition Monitoring to Digital TwinsEnergies · 2026