Applied Sciences

Coordinated Design and Adaptive Control of VSG Reactive-Power–Voltage Outer-Loop Parameters Under Stability and Steady-State Error Constraints

Dingyi Cheng, Tianshu Li, Guannan Bao, Zekun Kong, Deliang Chen, Yuanzhen Zhu, Cheng Wu

Key points

From the paper's conclusion
  • The resulting two-parameter stability region is then combined with the steady-state error constraints to construct a joint feasible region in the ku-kq plane for coordinated parameter selection.

Abstract

The voltage-regulation coefficient and reactive-power gain of the virtual synchronous generator (VSG) reactive-power–voltage outer loop have significant effects on system stability and steady-state performance. However, these two parameters are often designed independently, making it difficult to simultaneously satisfy stability and voltage-regulation requirements. This paper proposes a coordinated parameter design and adaptive control method under stability and steady-state error constraints. Using a small-signal model, the coupled effects of the voltage-regulation coefficient ku and the reactive-power gain kq on the eigenvalue distribution and small-signal stability constraint are analyzed. The resulting two-parameter stability region is then combined with the steady-state error constraints to construct a joint feasible region in the ku-kq plane for coordinated parameter selection. Based on this region, a voltage-deviation-driven adaptive strategy is developed. The voltage-regulation coefficient is increased when the PCC voltage deviation exceeds the allowable threshold. Meanwhile, the reactive-power gain is reduced when the resulting parameter combination no longer satisfies the stability constraint. Simulation results show that, under SCR = 1, the proposed strategy reduces the PCC voltage from 1.17 p.u. to 1.012 p.u. while maintaining stable operation. Stable responses are also obtained under the investigated SCR = 5 and SCR = 10 conditions, providing additional verification under different fixed grid-strength conditions. The method provides a practical framework for parameter tuning and adaptive adjustment of VSG-based grid-connected converters, particularly when PCC voltage-limit violations occur.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Coordinated Design and Adaptive Control of VSG Reactive-Power–Voltage Outer-Loop Parameters Under Stability and Steady-State Error Constraints — Science Skim