Causes of Azimuthal Air Temperature Biases on a 100 m Meteorological Gradient Tower
Lei Chu, Xinfeng Ling, Chunfeng Duan, Kaidi Zhang, Houfu Zhou, Cong Zhu, Yue Liu
Key points
From the paper's conclusion- Here, we address this gap by using a 100 m lattice tower at the Shouxian National Climate Observatory (32.5° N, 116.8° E), which has base and top widths of 10.0 m and 2.0 m, respectively.
Abstract
Azimuthal temperature biases in multi-level tower-mounted sensors have long been reported, yet their underlying physical causes remain unclear. In particular, three candidate mechanisms—flow blockage, structural-geometry effects, and instrument-to-instrument differences in radiative sensitivity—have rarely been disentangled within a single observational experiment. Here, we address this gap by using a 100 m lattice tower at the Shouxian National Climate Observatory (32.5° N, 116.8° E), which has base and top widths of 10.0 m and 2.0 m, respectively. East–west symmetric dual temperature sensors and independent bilateral anemometers were installed at 34, 50, 65, and 80 m, with an additional reference anemometer at 95 m. On 12 May 2025, the complete probe-and-shield assembly at 50 m was reversed east–west, whereas the other three levels remained unchanged as negative controls, thereby establishing a difference-in-differences (DID) framework. Using the top-mounted reference wind direction, the bilateral wind-speed difference shows no statistically significant shadow sector at any level, allowing us to reject the flow-blockage (tower-shadow) hypothesis. The structural baseline bias S(z) of the three un-swapped decreases monotonically in magnitude with height (from −0.92 °C at 34 m to −0.28 °C at 80 m) and tracks the height-dependent tower geometry, proxied by the face width W(z), linearly, with stable day–night behavior—pointing to a geometric/orientational origin. After the swap, the 50 m bias amplifies to 3–18 times the baseline and reverses seasonally; the inter-instrument difference in daytime shortwave response is significant (Δα = +46.27 × 10−3 °C/(MJ m−2 d−1), 95% CI [+5.71, +91.30]), whereas the nighttime net-longwave difference is directionally consistent but not significant (Δβ = +38.33 × 10−3 °C/(W m−2), 95% CI [−1.32, +70.78]). We conclude that instrument-swap-induced homogeneity breaks are more likely caused by inter-instrument differences in radiative-response sensitivity than by a constant offset. This finding has important implications for climate-network homogenization and for azimuthal quality control of tower-mounted sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- LCZ-Stratified Estimation of Near-Surface Air Temperature from Land Surface Temperature: Evidence from Central Xi’an, ChinaBuildings · 2026
- Experimental Comparison of the Effects of Symmetric and Unsymmetric Aerodynamic Corner Modifications on Surface Pressures of Tall BuildingsJournal of The Institution of Engineers (India): Series A · 2026
- Beyond the urban surface: bird-borne sensing reveals the atmospheric structure of urban heatbioRxiv · 2026
- Quantifying the Influence of Meteorological Factors on Diurnal Urban Thermal Directional Anisotropy Using UAV Observations and Controlled SimulationsLand · 2026
- Conditional topographic contribution to azimuth-dependent ambient-noise HVSR from network observations and 3D simulationsGeophysical Journal International · 2026
- Theoretical confirmation of temperature gradient characteristics in concrete bridges through refined thermal analysisCase Studies in Thermal Engineering · 2025