Unlocking Low-Carbon Heat: Geothermal Feasibility and Thermal Breakthrough in Carboniferous Sandstone Aquifers
Jack Alfred Johnson, Nicholas Shaw, Robert Knipe, Chrysothemis Paraskevopoulou
Key points
From the paper's conclusion- The results demonstrate that an open-loop doublet system is conditionally feasible within the Marchup Grit aquifer; however, long-term operational performance remains sensitive to thermal feedback (estimated at ~22 years analytically for a 300 m well spacing and 8–10 years numerically under a 130 m minimum spacing constraint at peak abstraction rates).
Abstract
Decarbonisation is crucial for mitigating climate change, with ground source heat pumps (GSHPs) playing a key role in reducing reliance on gas for space heating. This study investigates the potential of an open-loop GSHP system in the Carboniferous Millstone Grit of Ilkley, West Yorkshire, using Ilkley Lido and surrounding sports facilities as an example heating demand. The feasibility of systems installed at depths less than 150 m is examined, considering both shallow and deeper geological conditions. Available data on subsurface geology, hydrogeology, and geothermal gradients are utilised to characterise the formations and target depths, with cross-sectional models developed to assess the potential. The Marchup Grit aquifer is identified as the primary target due to its relatively shallow depth (~90 m), expected subsurface temperature (~14.5 °C), and moderate transmissivity. Additional geothermal potential is also considered in the Warley Wise Grit and Pendleside Limestone. The study contrasts borehole and field data with literature findings, including measurements at outcrop level of the Marchup Grit. To assess the feasibility of an open-loop GSHP system, a doublet configuration is simulated, matching the estimated heat demand of the facilities. The results demonstrate that an open-loop doublet system is conditionally feasible within the Marchup Grit aquifer; however, long-term operational performance remains sensitive to thermal feedback (estimated at ~22 years analytically for a 300 m well spacing and 8–10 years numerically under a 130 m minimum spacing constraint at peak abstraction rates). By reducing abstraction to 70% of the peak heating demand, long-term sustainability can be improved. Overall, while the system exhibits preliminary potential, commercial implementation remains subject to confirmatory site-specific borehole drilling, hydrochemical sampling, and long-duration pumping tests to validate reservoir capacity and optimise system longevity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility analysis of geothermal energy utilization in ultra-low temperature district heating networks: Effect of heat distribution in underground tunnelsRenewable Energy · 2026
- Geothermal Borefield Selection for Residential Buildings: Effects of Soil and Installation Limits on Cost and CarbonBuildings · 2026
- Thermal performance testing of shallow geothermal systems: Insights from field experiments and numerical modellingGeothermics · 2026
- Techno-economic analysis of a district heating system based on renewable sources in a touristic mountain villageJournal of Physics: Conference Series · 2026
- A Structured Evaluation of Key Factors for Shallow Geothermal Hybrid Heating and Cooling Systems in the Danube Region Using the Analytic Hierarchy ProcessProcesses · 2026
- Numerical investigation on the thermal performance of double U-type borehole heat exchanger based on an in situ thermal response testJournal of Renewable and Sustainable Energy · 2026