Reducing Hallucinations in Medical AI Through Citation Enforced Prompting in RAG Systems
Lukasz Pawlik, Stanislaw Deniziak
Altarum Institute · Kielce University of Technology
Key points
From the paper's conclusion- Overall, the findings demonstrate that prompting strategy selection is as critical for clinical reliability as model architecture.
Abstract
The safe integration of Large Language Models in clinical environments requires strict adherence to verified medical evidence. As part of the PARROT AI project, this study provides a systematic evaluation of how prompting strategies affect the reliability of Retrieval-Augmented Generation (RAG) pipelines using the MedQA USMLE benchmark (N=500). Four prompting strategies were examined: Baseline (zero-shot), Neutral, Expert Chain-of-Thought (Expert-CoT) with structured clinical reasoning, and StrictCitations with mandatory evidence grounding. The experiments covered six modern model architectures: Command R (35B), Gemma 2 (9B and 27B), Llama 3.1 (8B), Mistral Nemo (12B), and Qwen 2.5 (14B). Evaluation was conducted using the Deterministic RAG Evaluator, providing an objective assessment of grounding through the Unsupported Sentence Ratio (USR) based on TF-IDF and cosine similarity. The results indicate that structured reasoning in the Expert-CoT strategy significantly increases USR values (reaching 95–100%), as models prioritize internal diagnostic logic over verbatim context. In contrast, the StrictCitations strategy, while maintaining high USR due to the conservative evaluation threshold, achieves the highest level of verifiable grounding and source adherence. The analysis identifies a statistically significant Verbosity Signal (r=0.81,p<0.001), where increased response length serves as a proxy for model uncertainty and parametric leakage, a pattern particularly prominent in Llama 3.1 and Gemma 2. Overall, the findings demonstrate that prompting strategy selection is as critical for clinical reliability as model architecture. This work delivers a reproducible framework for the development of trustworthy medical AI assistants and highlights citation-enforced prompting as a vital mechanism for improving clinical safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evidence-based clinical question answering using retrieval-augmented generation (RAG) and open-source large language modelsScientific Reports · 2026
- Mitigating hallucinations in healthcare AI: a systematic review of evidence-based strategiesBMC Health Services Research · 2026
- Mitigating Hallucinations in Medical Question Answering on ESC Cardiology Guidelines: Evaluation and Retrieval OptimizationarXiv · 2026
- Authentic Sources, Potentially Unsafe Conclusions: Evidence Traceability Does Not Ensure Clinical Reliability in Retrieval-Augmented Generation for Perioperative IBD.Journal of multidisciplinary healthcare · 2026
- Retrieve-Then-Verify for Evaluating Evidence Support and Hallucination in Large Language Model-Generated Medical Information: Empirical Study.JMIR AI · 2026
- Automating expert-level medical reasoning evaluation of large language modelsnpj Digital Medicine · 2025