Apparent Ca Test Positivity and Crossmatch Reactivity in Donkeys from Italy: Intraspecies and Horse-Donkey Compatibility.
Chiara Bozzola, Enrica Zucca, Eva Spada, Luciana Baggiani, Roberta Perego, Daniela Proverbio
Dipartimento di Medicina Veterinaria e Scienze Animali (DIVAS), Università degli Studi di Milano, 26900 Lodi, Italy.
Key points
From the paper's conclusion- We estimated the apparent Ca positive-test frequency in 84 domestic donkeys and assessed donkey–donkey and horse–donkey crossmatch reactivity.
Abstract
Blood group distribution and serological compatibility are poorly characterized in donkeys. We estimated the apparent Ca positive-test frequency in 84 domestic donkeys and assessed donkey-donkey and horse-donkey crossmatch reactivity. Ca typing was performed using a commercial equine immunochromatographic assay. For donkey-donkey crossmatching, one major and one minor crossmatch were analyzed for each of the 77 Ca-concordant and 34 Ca-discordant pairs. Fifty-six of eighty-four donkeys yielded a positive result with the equine Ca assay (66.7%; 95% CI, 56.1-75.8%). Major combined macroscopic/microscopic reactivity occurred in 18/77 Ca-concordant and 11/34 Ca-discordant pairs, whereas minor combined reactivity occurred in 21/77 and 8/34 pairs, respectively. In crossed random-effects logistic models, the adjusted odds ratios for Ca-discordant versus Ca-concordant pairs were 1.56 (95% CI, 0.64-3.82) for major combined reactivity, 0.82 (95% CI, 0.32-2.10) for minor combined reactivity, and 1.57 (95% CI, 0.41-5.94) for major macroscopic reactivity; the minor macroscopic model was not estimable. Horse-donkey reactions were frequent and direction-dependent. When donkey plasma was tested against horse RBCs, combined reactivity occurred in 80/80 tests in the horse-donor/donkey-recipient dataset and in 76/76 tests in the reciprocal dataset, with macroscopic reactivity in 77/80 (96.3%) and 74/76 (97.4%), respectively. In the reciprocal horse-plasma/donkey-RBC direction, combined reactivity occurred in 53/80 (66.3%) and 51/76 (67.1%) tests, with macroscopic reactivity in 32/80 (40.0%) and 32/76 (42.1%), respectively. Ca concordance was not significantly associated with crossmatch reactivity in the present dataset, and Ca status alone did not account for the observed crossmatch-reactivity pattern.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Susceptibility of Donkey and Horse Sperm to Liquid-Storage Temperature.Reproduction in domestic animals = Zuchthygiene · 2026
- Frequency of ABO, Rh Subtypes, and Kell Antigen Among Blood Donors at Riyadh Regional Blood Bank: A Retrospective Cross-Sectional Study.Journal of clinical medicine · 2026
- Prevalence and genetic characterization of Cryptosporidium spp. and Enterocytozoon bieneusi in horses in central and western Inner Mongolia, China.Frontiers in veterinary science · 2026
- Molecular Survey of Selected Tick-Borne Pathogens and Genetic Diversity of Theileria equi in Donkeys from Croatia.Microorganisms · 2026
- Characterisation, development, and validation of an in-house antibody cell panel: A prospective cross-sectional study from a tertiary care hospital.The Indian journal of medical research · 2026
- ABO and Rhesus (D, C, c, E, and e) Antigen Frequencies Among Blood Donors in Saudi Arabia.Clinical laboratory · 2026