Rapid Quantification of Sodium Chloride in Aqueous Solutions Using Raman Spectroscopy and Partial Least Squares Regression
Julio Alberto Pavón-Moreno, Marisol Escorza-Reyes, Aarón Flores Gil, Juan Gabriel Flores Trujillo, Olena Benavides, Lelio De la Cruz May, Sergio Martinez-Vargas
Key points
From the paper's conclusion- This study presents a method based on Raman spectroscopy (785 nm; 350–2000 cm−1) combined with partial least squares regression (PLS-R) for estimating NaCl in simple aqueous solutions at concentrations between 0.02 and 4.0 mol·L−1.
Abstract
The rapid and non-destructive determination of sodium chloride (NaCl) in aqueous solutions is critical to food-process monitoring, pharmaceutical manufacturing, and the chlor-alkali and desalination industries. This study presents a method based on Raman spectroscopy (785 nm; 350–2000 cm−1) combined with partial least squares regression (PLS-R) for estimating NaCl in simple aqueous solutions at concentrations between 0.02 and 4.0 mol·L−1. Since Na+ and Cl− ions lack intrinsic Raman modes, the quantification was based on the modifications that ionic solvation induces on the hydrogen-bond network of water, mainly affecting the librational (450–780 cm−1) and H-O-H bending modes (~1640 cm−1). Four preprocessing strategies were systematically evaluated. The model with the combination of asymmetric least squares baseline correction and Savitzky–Golay smoothing (ALS-SG) provided the lowest root mean square error of cross-validation (RMSECV = 0.0608 mol·L−1), requiring only two latent variables (calibration coefficient of determination, R2cal = 0.9990 and cross-validated coefficient of determination, Q2CV = 0.9979). The holdout prediction set (n = 5) yielded a coefficient of determination (R2ext) of 0.9946 and a root mean square error of prediction (RMSEP) of 0.0681 mol·L−1, with an empirical lower limit of reliable prediction of ~0.18 mol·L−1. The holdout samples span 0.04–2.50 mol·L−1, so predictive performance between 2.50 and 4.00 mol·L−1 is supported by calibration and cross-validation only. Given the small size of this set, these figures are reported as a proof-of-concept indication and support the potential of the approach for NaCl monitoring in simple aqueous matrices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A dataset of Raman spectra with quantitative labels of mixtures of nitrate, nitrite and sulphate.Data in brief · 2026
- Raman spectroscopy enables non-destructive quantification of nitrate in C3 and C4 plants.Frontiers in plant science · 2026
- High-spatial-resolution characterization of hydroxide ion concentration in solutions: A novel strategy based on RGB color analysis.Talanta · 2026
- Handheld spatially offset Raman spectroscopy for the simultaneous quantification of key quality parameters in cosmetic raw materials.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Machine learning-integrated multi-wavelength SPR sensor based on aluminum-doped zinc oxide and 2D amorphous silicon for high-precision salinity measurementBiomedical Optics Express · 2026
- Predicting the Aqueous Solubility of Neutral Organic Compounds by Reversed-Phase Liquid Chromatography.Journal of separation science · 2026