Direct Determination of Readily Accessible Quercetin-Reactive Aluminum and Ascorbate-Reducible, Ferrozine-Reactive Iron in Cosmetic Emulsions
Georgia Eleni Tsotsou, Dimitra Dremetsika, Georgia Bakara, Mirofora Pilakouta
Key points
From the paper's conclusion- We developed smartphone-based colorimetric assays relying on metal–reagent complexation directly in oil-in-water (O/W) emulsions, without digestion or extraction.
Abstract
Aluminum in antiperspirants is relevant to formulation control and compliance, whereas reactive iron can promote oxidative instability in emulsions. We developed smartphone-based colorimetric assays relying on metal–reagent complexation directly in oil-in-water (O/W) emulsions, without digestion or extraction. The aluminum assay measures quercetin-reactive aluminum from aluminum chlorohydrate (ACH). Calibration data were fitted by linear regression (R2 ≥ 0.971). Acceptable accuracy (relative bias within ± 8.5%) and intermediate precision (CV ≤ 9.4%) were obtained upon quality control (QC) analysis (above the LLOQ). Relative bias in commercial antiperspirants and corresponding in-house preparations was within ± 15.2%. The iron assay measures ascorbate-reducible, ferrozine-reactive iron. Its calibration data were also fitted by linear regression (R2 ≥ 0.981), while QC analysis showed acceptable accuracy (relative bias within ± 13.7%) and intermediate precision (CV ≤ 12.6%). Comparison with portable energy-dispersive X-ray fluorescence (EDXRF) yielded a regression slope of 1.14 and an intercept of 0.40 μg/g, suggesting a proportional difference and a possible constant component. Common chelators and certain metals interfered with both assays. The effect of interferents in commercially relevant concentration was, however, minimal (relative bias within ± 15.2% for Al and at 4.5% for a Co/Cu/Fe-fortified model emulsion) after matrix matching or dilution. Although mostly inferior in terms of technical characteristics compared to established instrumental methods, this methodology is sufficiently accurate, precise and selective under the defined conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Miniaturized chromate-free chloride assay in fish sauce based on linear height calibration of AgCl precipitate in inverted microtubesGreen Analytical Chemistry · 2026
- Assessment of Dermally Bioaccessible Elements by Sweat-Simulated Extraction: Analytical Approach and Application to Tattoo InksMolecules · 2026
- Mercury contamination in skin-lightening cosmetic products across market pathways: Implications for consumer exposure and risk-based surveillance.Journal of hazardous materials · 2026
- Optimisation and Validation of a Microscale FRAP Assay with Matrix-Matched (Interaction-Corrected) Blanking for Accurate Antioxidant Capacity Assessment of Honeys.Methods and protocols · 2026
- Green fatty-acid-based hydrophobic NADES with ultrasonic-assisted dispersive liquid-liquid micro extraction for fluorometric detection of rhodamine 6G in cosmetic products.Analytical methods : advancing methods and applications · 2026
- Secondary and Recycled Aluminum as a Reactive Fuel: Feedstock, Processing, Combustion, and Energy ConversionEnergies · 2026