Robotic Venipuncture with Sequential Needle-Tip Realignment and Probe-Induced Vessel Displacement Compensation
Seungyeon Shin, Kiwon Yeom
Key points
From the paper's conclusion- These results demonstrate that sequential compensation of probe-induced vessel displacement and physical needle-tip misalignment enables accurate and repeatable robotic venipuncture using a comparatively simple insertion architecture without continuous multi-DOF needle steering.
Abstract
Robotic venipuncture systems can accurately localize vascular targets using near-infrared (NIR) and ultrasound (US) imaging. However, image-based localization does not guarantee accurate physical needle placement. Residual errors arising from sensor-to-robot registration, mechanical assembly, and needle mounting can cause misalignment of the physical needle tip, while contact pressure of the US probe on soft tissue can displace the vessel from its initially estimated position. This study presents a sequential error-compensation method that addresses residual positioning errors before needle insertion, followed by US-based vessel-arrival detection and bounded stopping during insertion. Monocular NIR imaging is used to determine the vessel centerline and planar target on the skin surface, while US imaging provides the corresponding vessel depth coordinate for three-dimensional target localization. Probe-induced vessel displacement is incorporated into the insertion geometry to determine the required needle angle and insertion length. After insertion-path planning, the physical needle tip is redetected in the NIR image and realigned with the planar vessel target. The final insertion angle is then established and needle advancement is performed using the independent linear insertion axis. By compensating these error sources prior to penetration, the subsequent insertion stage is simplified to linear needle advancement without continuous high-DOF steering. During insertion, US-based vessel-arrival detection is combined with an independent maximum insertion-length constraint to provide bounded stopping. In phantom experiments, NIR-based needle-tip alignment increased the pre-insertion alignment success rate from 14.0% to 94.0%, while probe-induced vessel displacement compensation increased insertion success from 58.0% to 98.0%. The complete autonomous procedure achieved a 96.7% success rate. These results demonstrate that sequential compensation of probe-induced vessel displacement and physical needle-tip misalignment enables accurate and repeatable robotic venipuncture using a comparatively simple insertion architecture without continuous multi-DOF needle steering.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Deep Learning Based Robotic Ultrasound System for Automated Probe Alignment and Precise Finger Joint Localization with Underwater Refraction Compensation.IEEE transactions on medical robotics and bionics · 2026
- Autonomous Robotic Respiratory Motion Compensation and Needle Insertion via MRI Correspondence Models for CT‐Guided Hepatic Percutaneous ProceduresThe International Journal of Medical Robotics and Computer Assisted Surgery · 2026
- Ultrasound-Led Multimodality Imaging-Guided Robotic Needle Insertion With Respiratory Phase Consistency in Phantom and Animal Models.Ultrasound in medicine & biology · 2026
- Toward Trustworthy Robot-Assisted Sliding Palpation for Shallow Vessel Localisation with a Calibrated Digital TwinarXiv · 2026
- A VR Training System for Robot-Assisted Vascular Intervention with Dual-Mode Control and Model-Based Interaction ResponsearXiv · 2026
- In Situ vs. Monitor-Based: Evaluating Augmented Reality for Ultrasound-Guided Peripheral Venous Catheter Insertion.IEEE transactions on visualization and computer graphics · 2026