From the paper's conclusion
  • This study proposes a coordinated dead-zone inverse compensation (DIC) and improved active disturbance rejection control (IADRC) strategy, termed DIC-IADRC.

Abstract

Pump-controlled hydraulic die cushions offer energy-efficient actuation, but accurate position control is challenged by flow dead-zone nonlinearity, parameter perturbations, and external load disturbances. This study proposes a coordinated dead-zone inverse compensation (DIC) and improved active disturbance rejection control (IADRC) strategy, termed DIC-IADRC. A mechanism-based dead-zone model is derived by considering leakage across multiple piston-pump friction pairs and oil compressibility. A smooth inverse compensator is constructed using experimentally identified parameters, and its compensation error is explicitly introduced into a high-order sliding mode observer (HOSMO) as a known input for finite-time disturbance estimation. The improved ADRC further incorporates a full-range fast tracking differentiator (FFTD) and nonlinear state error feedback (NLSEF) to suppress differentiation chattering and balance response speed and smoothness. The strategy is evaluated on a physical pump-controlled hydraulic die-cushion test bench through step tracking, sudden-load disturbance rejection, and sinusoidal tracking experiments, with PID, standard ADRC, and DIC-ADRC as benchmarks. Compared with PID, DIC-IADRC reduces step overshoot by 79.4%, steady-state mean absolute error (MAE) by 83.6%, peak sudden-load tracking error by 64.9%, and maximum sinusoidal tracking deviation by 35.7%. It also outperforms standard ADRC and DIC-ADRC across the tested operating conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Position Control of Pump-Controlled Hydraulic Die Cushions Based on Dead-Zone Inverse Compensation and Improved Active Disturbance Rejection Control — Science Skim