Robust Backstepping Control of Parallel-Connected Inverters Supplying an Induction Motor Under Inverter Fault Conditions
Zaidi Elyazid, Habib Benbouhenni, Abdelhakim Mabrek, Khoudir Marouani, Alin Gheorghita Mazare, Laurentiu Mihai Ionescu, Nicu Bizon
Key points
From the paper's conclusion- The experimental findings indicate that the proposed controller successfully sustains stable speed regulation, enhances current sharing, and significantly mitigates circulating currents and torque ripples during fault conditions.
Abstract
This paper proposes a fault-robust backstepping-based control strategy for induction motor (IM) drives fed by parallel-connected voltage-source inverters (VSIs). The developed control scheme is engineered to achieve precise speed tracking, optimal current sharing among parallel inverter legs, and effective suppression of zero-sequence circulating currents (ZSCCs) under both normal operation and inverter fault scenarios. Initially, a comprehensive mathematical model of the parallel inverter-fed IM drive is formulated in the synchronous reference frame, rigorously incorporating the inter-inverter coupling dynamics. Utilizing Lyapunov stability theory, a nonlinear backstepping controller is subsequently synthesized to guarantee closed-loop stability and the asymptotic convergence of tracking errors. To evaluate the robustness and fault-tolerance of the proposed method, open-circuit faults in the inverter power switches are investigated. The dynamic impacts of these faults on motor speed, electromagnetic torque, stator currents, current distribution, and ZSCCs are thoroughly analyzed through both simulation and experimental validations. The experimental findings indicate that the proposed controller successfully sustains stable speed regulation, enhances current sharing, and significantly mitigates circulating currents and torque ripples during fault conditions. Furthermore, comparative evaluations against conventional proportional–integral controllers highlight the superior transient response and enhanced fault resilience of the suggested approach. Ultimately, these results substantiate the efficacy of the proposed backstepping-based control framework in ensuring highly reliable operation of parallel inverter-fed IM drives across diverse operating states.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental Validation of a Hybrid PI–SO-SMC Approach for Zero-Sequence Circulating Current Suppression in Parallel InvertersElectronics · 2026
- Backstepping-Based Control of Two Series-Connected 5-Փ PMSMs Used for Small and Medium Electric Ship Propulsion SystemsJournal of Marine Science and Engineering · 2026
- Fault-Tolerant Control of Three-Phase Converter Motor Drive System Based on FCS-MPCEnergies · 2026
- A Novel Dynamic Configuration for Long-Term Fault-Tolerant Operation of Open-End Winding Induction MotorsMachines · 2026
- An Induction Machine Speed Regulation System Based on Adaptive Terminal Sliding Mode Controller With Barrier FunctionAdvanced Control for Applications · 2026
- Optimal Fractional-Order Backstepping Control of Dual-Star Induction Generator Wind Energy Conversion Systems Under Wind and Parameter UncertaintiesWind · 2026