An Asymmetric Magnetorheological Damping Knee Exoskeleton with a One-Way Bearing for Impact Attenuation During Downhill Walking
Lin Li, Yaqi Mi, Xinqin Gao, Xupeng Wang, Youzhi Lu, Zizhuo Wang
Key points
From the paper's conclusion- These findings indicate that direction-selective impact attenuation can be enabled by partially transferring damping-direction selection from the control layer to the mechanical structure, without reliance on accurate and complete gait-phase recognition, while the risk of sustained damping during knee extension caused by control delays or misclassification is reduced.
Abstract
During downhill walking, the human knee joint is subjected to a relatively high transient flexion velocity and impact load during the initial foot-contact phase, whereas low motion resistance is required during the subsequent knee-extension recovery phase. To address the difficulty that conventional bidirectional-damping knee exoskeletons have in simultaneously providing effective impact attenuation and preserving freedom of knee extension, an asymmetric-damping knee exoskeleton is proposed in this study. The proposed exoskeleton is based on the coaxial series integration of a magnetorheological (MR) damper and a one-way bearing. The mechanical characteristics of the one-way bearing, which locks in the knee-flexion direction and overruns freely in the knee-extension direction, are exploited so that direction-selective damping is enabled, characterized by high resistance for impact attenuation during knee flexion and low resistance during knee-extension recovery. In addition, an event-triggered control strategy based on the jerk signal measured by a shank-mounted inertial measurement unit (IMU) is employed so that the MR damper is driven into a high-damping state only after a landing impact is detected; thus, dependence on complete gait-phase recognition is reduced. Based on a single-degree-of-freedom human–exoskeleton coupled dynamic model and a Bingham constitutive model, MATLAB R2024a simulations were conducted under three conditions: without an exoskeleton, with a symmetric-damping exoskeleton, and with the proposed asymmetric-damping exoskeleton. In addition, finite element analysis of the magnetic-field distribution within the damper was performed using COMSOL 5.6. The results indicate that, under the representative operating conditions considered in this study, the peak angular velocity of the knee joint is reduced by the asymmetric-damping configuration compared with the condition without an exoskeleton. Although the peak-suppression performance of the proposed configuration is slightly lower than that of the symmetric-damping configuration, the sustained resistance during the knee-extension recovery phase is substantially reduced, and a trade-off between impact attenuation and freedom of motion is demonstrated. These findings indicate that direction-selective impact attenuation can be enabled by partially transferring damping-direction selection from the control layer to the mechanical structure, without reliance on accurate and complete gait-phase recognition, while the risk of sustained damping during knee extension caused by control delays or misclassification is reduced. This structure–control collaborative approach provides a new design pathway for semi-active exoskeletons to reduce control complexity, improve the determinacy of the damping direction, and support the development of lightweight and low-power assistive technologies for downhill walking.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Modeling and Control of a Hybrid Passive/Semi-Active Magnetorheological Recoil Damper with a Pressure-Actuated Stroke-Limiting ValveActuators · 2026
- Biomechanical Trade-Offs in Knee Brace Stiffness: Dynamic Stability During Single-Leg Lateral Landings in Young MalesIEEE Transactions on Neural Systems and Rehabilitation Engineering · 2026
- Dual-loop control of lower-limb exoskeletons using adaptive admittance and nonlinear extended state observer-based active disturbance rejectionRobotica · 2026
- Effects of Flexible and Semirigid Knee Braces on Meniscal and Ligament Loading During Landing Impact.Bioengineering (Basel, Switzerland) · 2026
- A Nonlinear Disturbance Observer-Based Super-Twisting Sliding Mode Controller for a Knee-Assisted Exoskeleton RobotAutomation · 2026
- A pressure-based motion intention recognition strategy for phase-specific knee exoskeleton assistance during sit-to-stand.Frontiers in physiology · 2026