Actuators

Closed-Loop Identification and Decoupled MIMO FxLMS Control of Multi-Tonal Foundation Vibration in a Magnetically Suspended Support System

Feng Xiong, Wenhao Xu, Hang Yin, Yan Li, Neng Zhang, Tianqi Yin

Computational

Key points

From the paper's conclusion
  • The results indicate that, with PID feedback maintaining stable levitation, the compensating electromagnetic forces of the AMBs can suppress the foundation vibration response formed by multiple non-synchronous low-frequency tonal components, achieving coordinated control over multi-tonal vibration suppression and stable rotor levitation.

Abstract

This paper addresses the vibration response produced at the supporting foundation by multiple low-frequency tonal components transmitted through magnetic bearing supports. A composite active magnetic bearing (AMB) control method is proposed in which the measured foundation vibration serves as the direct control objective. With a PID feedback loop maintaining five-degree-of-freedom (5-DOF) stable levitation of the rotor, the complex frequency-response matrices from the control currents to the foundation accelerations at the target frequencies are identified in the closed loop by simultaneous multi-channel excitation, with random initial phases combined with correlation integration. The conjugate transpose of the pseudo-inverse of each matrix forms a decoupling matrix, which is embedded in the reconstruction of the filtered reference signals to build a narrowband MIMO FxLMS feedforward loop; together with the PID feedback loop, this constitutes the composite control system. MATLAB/Simulink simulations show that the controller converges stably under 15% amplitude mismatch, 5° phase mismatch and broadband background noise. In experiments on a 5-DOF AMB test rig, the average attenuations of the three target tonal components at 34.5, 37 and 41.5 Hz over five foundation measurement points reach 18.1, 18.0 and 18.36 dB, respectively, with a maximum attenuation of 32.8 dB, and no pronounced amplification is observed outside the target frequencies. After the feedforward loop is engaged, the rotor displacement peaks at approximately ±0.08 mm during the transient and then settles within ±0.05 mm, far below the 0.3 mm working air gap. The results indicate that, with PID feedback maintaining stable levitation, the compensating electromagnetic forces of the AMBs can suppress the foundation vibration response formed by multiple non-synchronous low-frequency tonal components, achieving coordinated control over multi-tonal vibration suppression and stable rotor levitation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Closed-Loop Identification and Decoupled MIMO FxLMS Control of Multi-Tonal Foundation Vibration in a Magnetically Suspended Support System — Science Skim