Closed-Loop Identification and Decoupled MIMO FxLMS Control of Multi-Tonal Foundation Vibration in a Magnetically Suspended Support System
Feng Xiong, Wenhao Xu, Hang Yin, Yan Li, Neng Zhang, Tianqi Yin
Key points
From the paper's conclusion- The results indicate that, with PID feedback maintaining stable levitation, the compensating electromagnetic forces of the AMBs can suppress the foundation vibration response formed by multiple non-synchronous low-frequency tonal components, achieving coordinated control over multi-tonal vibration suppression and stable rotor levitation.
Abstract
This paper addresses the vibration response produced at the supporting foundation by multiple low-frequency tonal components transmitted through magnetic bearing supports. A composite active magnetic bearing (AMB) control method is proposed in which the measured foundation vibration serves as the direct control objective. With a PID feedback loop maintaining five-degree-of-freedom (5-DOF) stable levitation of the rotor, the complex frequency-response matrices from the control currents to the foundation accelerations at the target frequencies are identified in the closed loop by simultaneous multi-channel excitation, with random initial phases combined with correlation integration. The conjugate transpose of the pseudo-inverse of each matrix forms a decoupling matrix, which is embedded in the reconstruction of the filtered reference signals to build a narrowband MIMO FxLMS feedforward loop; together with the PID feedback loop, this constitutes the composite control system. MATLAB/Simulink simulations show that the controller converges stably under 15% amplitude mismatch, 5° phase mismatch and broadband background noise. In experiments on a 5-DOF AMB test rig, the average attenuations of the three target tonal components at 34.5, 37 and 41.5 Hz over five foundation measurement points reach 18.1, 18.0 and 18.36 dB, respectively, with a maximum attenuation of 32.8 dB, and no pronounced amplification is observed outside the target frequencies. After the feedforward loop is engaged, the rotor displacement peaks at approximately ±0.08 mm during the transient and then settles within ±0.05 mm, far below the 0.3 mm working air gap. The results indicate that, with PID feedback maintaining stable levitation, the compensating electromagnetic forces of the AMBs can suppress the foundation vibration response formed by multiple non-synchronous low-frequency tonal components, achieving coordinated control over multi-tonal vibration suppression and stable rotor levitation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-sensing and adaptive composite fault-tolerant control strategy for magnetic-liquid double suspension bearings under sensor failures.The Review of scientific instruments · 2026
- System Identification and Robust Control Method for Magnetic Bearings in Ship Propulsion Shaft SystemsJournal of Marine Science and Engineering · 2025
- MIMOS: A Toolbox for Multivariable Modal IdentificationarXiv · 2026
- RSAS-FxLMS: A Robust Active Noise Control Method for Vibrator Operation Noise in Precast Beam PlantsApplied Sciences · 2026
- Platform-Motion Response Evolution and Predicted TDB-Clearance Risk of a Ship-Mounted Flexible Rotor–Active Magnetic Bearing SystemMathematics · 2026
- Active Maglev Vibration Isolation via a Slim Halbach Array Electromagnetic ActuatorAerospace · 2026