Breast Ultrasound Classification Under Cross-Dataset Shift: A Multi-Seed Benchmark of Convolutional Networks, a Vision Transformer, and a Self-Supervised Foundation Model
Ervin Ramollari, Narasimha Rao Vajjhala, Rajesh Kumar, Komal Ramchandani, Ranjeeta Mahraj, Khalid Hussain
Key points
From the paper's conclusion- We fine-tuned ResNet-50, EfficientNet-B0, a supervised Vision Transformer (ViT-B/16), and self-supervised DINOv2 under one shared protocol on the official BUS-BRA five-fold partitions, each fold with three seeds, and on three case-grouped hold-out splits, and evaluated every trained model unchanged on the Breast Ultrasound Images (BUSI) dataset.
Abstract
Deep-learning classifiers for breast ultrasound are usually evaluated on images from their training institution, and self-supervised foundation models are increasingly proposed as more transferable than supervised networks; whether ranking ability, decision thresholds, and probability calibration survive a change in institution has rarely been tested under leakage-controlled conditions. We fine-tuned ResNet-50, EfficientNet-B0, a supervised Vision Transformer (ViT-B/16), and self-supervised DINOv2 under one shared protocol on the official BUS-BRA five-fold partitions, each fold with three seeds, and on three case-grouped hold-out splits, and evaluated every trained model unchanged on the Breast Ultrasound Images (BUSI) dataset. The supervised models largely retained their discrimination externally. ResNet-50 had the highest mean area under the receiver operating characteristic curve under the official folds, but no criterion separated it from ViT-B/16, whose small hold-out advantage at the decision threshold did not recur. In every official-fold run, both models labeled a larger share of BUSI than of BUS-BRA images malignant, although prevalence was the same—a shift that temperature scaling cannot correct. Top-label calibration error also understated malignant-class miscalibration. Full-frame DINOv2 did not fit its training data in any run, although exploratory lesion cropping produced good discrimination. External evaluations should report operating-point transport and class-wise calibration alongside discrimination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Breast Tumor Segmentation in Automated Breast Ultrasound: A Scoping Review of Deep Learning Approaches (2020–2026)BioMedInformatics · 2026
- Comparative evaluation of vision transformers and convolutional networks for breast ultrasound image classificationExploration of Medicine · 2026
- Development and Evaluation of a Transformer-Based Multi-Scale Feature Model for the Classification of Benign and Malignant Breast Lesions in Ultrasound Image.Ultrasonic imaging · 2026
- Auxiliary-Data Governance in Breast Ultrasound Segmentation: A Multi-cohort Audit of Annotation Compatibility and Negative Transfer.Journal of imaging informatics in medicine · 2026
- Dense Breast Tissue Segmentation under Limited Annotation: Comparing CNNs, Transformers, Self-Supervision, and Prompting.medRxiv : the preprint server for health sciences · 2026
- Self-supervised learning and transformer-based technologies in breast cancer imagingFrontiers in Radiology · 2025