Frontiers in Veterinary Science

Feasibility of the BioTrace pain sensor for objective physiologic monitoring of nociceptive responses in caprine models

Ava F. Mullin, Tatum B. Nelson, Marty Kacsh, Brian M. Shoemake, Kallie J. Hobbs

Key points

From the paper's conclusion
  • This technology warrants further evaluation as an objective physiologic monitoring tool that may complement pain assessment in caprine patients and support future research and clinical applications in ruminant pain management.

Abstract

Background Pain assessment in goats relies largely on subjective behavioral and physiologic indicators that are susceptible to observer bias. PainTrace ® is a non-invasive device that records skin-surface electrophysiologic signals associated with autonomic responses to nociceptive stimulation; however, it has not been evaluated in goats. Objective This study aimed to evaluate the feasibility of using PainTrace ® to detect nociceptive responses in healthy goats. Animals Five healthy adult mixed-breed goats (three does and two wethers, aged 1–2 years and weighing 20–35 kg) were selected from a university teaching herd. Methods PainTrace ® sensors were placed bilaterally over the transverse processes of C2 following hair clipping and skin preparation. Continuous monitoring of electrical activity of the autonomic nervous system was performed wirelessly. Mechanical nociceptive stimulation was applied to the lateral claw of the right thoracic limb using a handheld pressure algometer until limb withdrawal occurred. Each goat received three algometer applications approximately 60 s apart per session, with one session per day on three consecutive days (9 applications per goat; 45 applications in total). There was no separate control group; however, light digital pressure was applied before the use of the algometer, and a 10-s signal period preceding each application served as a within-animal control. Algometer measurements, time points, and PainTrace ® tracings were aligned, and associations between applied force and the maximum PainTrace ® signal change were assessed using linear mixed-effects models with the goat treated as a random effect. Results All goats tolerated the placement of sensors without adverse effects or skin irritation. The PainTrace ® output increased during nociceptive stimulation and demonstrated significant associations with applied pressure during the initial application of each session ( p = 0.006); however, this association was not observed during the second or third applications. Signal variability was greater during nociceptive stimulation than during control conditions in all paired observations (exploratory analysis). Conclusion and clinical relevance The PainTrace ® recording system was found to be feasible and well tolerated in goats, and preliminary data suggest that the signal may vary with applied pressure. This technology warrants further evaluation as an objective physiologic monitoring tool that may complement pain assessment in caprine patients and support future research and clinical applications in ruminant pain management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Feasibility of the BioTrace pain sensor for objective physiologic monitoring of nociceptive responses in caprine models — Science Skim