Frontiers in Toxicology

Addressing the challenges of visual inspection for the effective isolation and characterization of microplastics in ingestion studies

E. Carreras-Colom, O. Rodríguez-Romeu, M. Carrassón, M. Constenla, S. Dallarés, A. Higueruelo, L. Muns-Pujadas, F. Padrós,

Key points

From the paper's conclusion
  • These improvements reduce contamination risks and false positives, thereby enhancing the reliability of visual inspection for microplastic and mesoplastic analysis.

Abstract

Visual inspection is one of the most commonly used techniques for isolating and identifying micro- and mesoplastics in marine organisms. However, it has been associated with a number of limitations, including limited accuracy and sensitivity, high false-positive rates, and contamination risks. Alternative approaches such as digestion-assisted and density-separation techniques offer their own advantages but may hinder multidisciplinary integration, as they inevitably result in the loss of biological context. This work combines a structured literature review with laboratory testing of easy-to-implement measures, including an isolation device, that improve the reliability of visual inspection. The review examined isolation and identification methods and associated quality assurance and quality control (QA/QC) practices in 297 articles published between 2011 and 2022. One of the main trends identified was that digestion-assisted procedures were more commonly associated with comprehensive contamination prevention measures, whereas studies relying on visual inspection generally reported fewer preventive measures, highlighting an opportunity to strengthen QA/QC in visual inspection workflows. Nevertheless, incomplete reporting of contamination monitoring was common across methods, with many studies omitting the results of air controls and procedural blanks (92 studies; 31.0%) or not describing the use of controls at all (85; 28.6%), reinforcing the need to raise awareness of the importance of implementing robust QA/QC practices. Measures tested included hermetic measures covering the workspace to reduce contamination and using wet mounts and optical microscopy to improve discrimination of fiber-shaped items. Under the tested conditions, the isolation device achieved a model-estimated reduction in airborne particle deposition rate of approximately 87%. Finally, visual classification based on morphological characteristics yielded a VISR of 0.97 for distinguishing between plastic and non-plastic ( i.e ., cellulose) fibers. These improvements reduce contamination risks and false positives, thereby enhancing the reliability of visual inspection for microplastic and mesoplastic analysis. This enhanced protocol not only allows for more reliable analysis of digestive contents but also facilitates the detection of potentially anthropogenic fibers, such as cellulosic-based polymers, shedding light on the complex presence of various contaminants in marine ecosystems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers