Design and proof of concept of a CRISPR/Cas13a-catalytic hairpin assembly framework for circulating microRNA detection in sepsis
Despina Panteleon, Maria-Nikolina Kerpinioti, Irene Pierrakea, Maria Electra Pavli, Spiros Giannopoulos, Nefeli Zormpa-Sfaellou, Konstantinos Anastasopoulos, Andreas Katsaros,
Key points
From the paper's conclusion- We propose a diagnostic framework combining CRISPR/Cas13a molecular recognition with a Catalytic Hairpin Assembly amplification circuit.
Abstract
Sepsis remains a leading cause of mortality worldwide, largely because early diagnosis is slow. Current biomarkers such as C-reactive protein and procalcitonin lack specificity and need up to 24 h to peak, delaying diagnosis in a condition where each hour increases mortality risk. Circulating microRNAs are promising early biomarkers, reflecting rapid molecular changes in the host response to infection. We propose a diagnostic framework combining CRISPR/Cas13a molecular recognition with a Catalytic Hairpin Assembly amplification circuit. Cas13a is programmed to recognize a short microRNA; on activation it cleaves a synthetic substrate collaterally, releasing an initiator that triggers an enzyme-free amplification cascade. In a proof-of-concept experiment a complete redesigned hairpin set (H0, H1 and H2) raised the share of the hairpin pool migrating as the H1-H2 duplex from approximately 34% to approximately 90% relative to a published set used in the same architecture, measured as band intensity in parallel lanes of a single gel. This is reported as a preliminary observation: the comparison rests on technical replicates of one reaction and lacks the no-target control that would establish target-dependent operation of the complete cascade. The system is designed for integration into a portable microneedle-microfluidic biosensor that would permit minimally invasive, serial sampling with an end-to-end assay time of approximately 4 h per measurement; that device has not been built and is described here as a specification. The two microRNAs were chosen by exhaustive screening of a public whole-blood cohort. They separate septic patients from healthy volunteers well (ROC-AUC 0.95) but separate them from patients with non-infectious inflammation poorly (ROC-AUC 0.64), and no panel of up to 263 curated microRNAs improved on that second figure, which is the comparison that matters clinically. That evidence comes from whole blood, a cell-associated compartment, whereas the proposed device would sample interstitial fluid, which is cell-free; performance in the intended sample therefore remains an open question. This article presents a hypothesis and a design, together with the computational and bench evidence that bears on them. No sensitivity, specificity or clinical performance is claimed, and the experiments that would test the proposal are set out explicitly.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A target amplification-free CRISPR biosensor with digital microfluidic processing for microRNA profiling in AI-enhanced pediatric sepsis diagnosis.Biosensors & bioelectronics · 2026
- Autocatalytic Cas13a biosensor enabled by RNA-nanocircles for ultrasensitive RNA detectionnpj Biosensing · 2026
- Engineering a leakage-resistant CHA-CRISPR/Cas12a biosensor via cis-cleavage-triggered split activator assembly for ultrasensitive miRNA detection.Biosensors & bioelectronics · 2026
- Orthogonal Cas13a/Cas12a cascade for one-pot amplification-free detection of miRNA-21.Talanta · 2026
- Isothermal miRNA Detection via Ligation-Dependent CRISPR/Cas13a Activation.ACS omega · 2026
- Re-Engineering CRISPR-Cas12a into a Multimodal Biosensing Platform with Programmable Precursor crRNAAnalytical Chemistry · 2026