Digital three-dimensional planning combined with 3D-printed patient-specific guide-assisted step-cut osteotomy for correction of old cubitus varus deformity: a case report.
Xiaofan Huang, Fulin Tang, Jialin Zhuang, Weikun Li
Department of Upper Limb, Mianyang Orthopaedic Hospital, Mianyang, Sichuan, China.
Key points
From the paper's conclusion- We report an 18-year-old male patient who developed progressive cubitus varus deformity 13 years after conservative treatment of a right supracondylar humeral fracture.
Abstract
Cubitus varus is the most common long-term complication following supracondylar humeral fractures. Although traditional step-cut osteotomy yields reliable clinical outcomes, the intraoperative osteotomy direction and angle remain largely dependent on the surgeon's experience, resulting in suboptimal precision. Although digital three-dimensional (3D) planning and 3D-printed patient-specific guides have been shown to improve osteotomy accuracy, their application in adolescent patients with long-standing cubitus varus deformity has rarely been reported. We report an 18-year-old male patient who developed progressive cubitus varus deformity 13 years after conservative treatment of a right supracondylar humeral fracture. Preoperatively, the carrying angle was -19°, with mildly restricted elbow motion and no ulnar nerve symptoms. Using mirror-image-based 3D digital planning, we designed and 3D-printed a patient-specific step-cut osteotomy guide and performed corrective osteotomy with lateral locking plate fixation. Intraoperatively, the guide was stably apposed to the bone surface, enabling precise execution of the osteotomy without displacement or interference. At 12-month follow-up, both the carrying angle and humeral-elbow-wrist angle had improved from -19° to 6.5°, elbow flexion-extension range improved from 5°-120° to 0°-135°, and the Mayo Elbow Performance Score was 95. No complications such as nonunion or nerve injury occurred, and the patient was satisfied with the surgical outcome. The combination of digital 3D planning and 3D-printed guide-assisted step-cut osteotomy may significantly enhance osteotomy accuracy and surgical safety, offering an effective approach for treating long-standing cubitus varus in adolescents. Nevertheless, given that this is a single-case report, broader studies are warranted to confirm its advantages.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D accurate osteotomy for pediatric cubitus varus deformity using a custom-matched surgical osteotomy template combined with a reduction template via a limited lateral incision: a case report and literature review.Frontiers in surgery · 2026
- Improved range of motion following correction osteotomy for varus malunited proximal humerus fractures with 3-dimensional planned cutting guides: a case series.JSES international · 2026
- In-House 3D Planning for Corrective Osteotomy of the Distal Radius: Prospective Cohort Study With 1-Year Radiological and Clinical Follow-Up.JMIR perioperative medicine · 2026
- Digital simulation and 3D-printed guide-assisted surgical correction of a complex pediatric hip deformity: a case report and literature review.Frontiers in pediatrics · 2026
- Medial Hemiplateau High-Tibial Osteotomy Technique for Varus Tibial Plateau Malunion.Arthroscopy techniques · 2026
- Diaphyseal forearm malunions with distal radioulnar joint instability treated by 3D-planned osseous correction.The Journal of hand surgery, European volume · 2026