Early outcomes following Duramesh™ implantation for abdominal wall closure: the Croydon experience.
Lawrence Nip, Sarah Zhao, Sajid Malik, Reif Hwang, Jessica Quimpo, Eslam Ghazy, Matt Dunstan, Rhys Thomas,
The Abdominal Wall Unit, Croydon University Hospital, London, United Kingdom.
Key points
From the paper's conclusion- There is ongoing debate about whether to repair simple and small midline ventral hernias with planar mesh or suture. Our short-term outcomes suggest Duramesh is safe in this cohort and can be technically convenient in certain situations.
Abstract
INTRODUCTION: Mesh suture, or Duramesh™, is gaining traction for abdominal wall closure and ventral hernia repair. However, published data are limited to US case series and institutional registries. Use in UK and European cohorts remains undocumented. This is the first UK series describing indications and outcomes following Duramesh implantation. METHODS: This is a retrospective case series from a medium-sized tertiary abdominal wall unit in the UK. Institutional implant logs of consecutive patients from 1st Sep 2023 to 8th June 2025 were cross-examined to identify relevant patients. Chart review was performed and the indications and outcomes analysed using descriptive statistics. Subgroups were compared with chi-squared and Mann-Whitney U tests. RESULTS: In total, 73 patients were included in this series, with a median follow-up of 227 days. Indications for Duramesh implantation included ventral hernia repair (n = 63; 86%) and abdominal wall closure (n = 10; 14%). Regarding ventral hernias, the most common location was M3 (n = 47; 76%) and median defect size was 2 cm. Planar mesh was used concurrently in 22% (n = 16) of cases. The 90-day surgical site occurrence rate was 22%. There were no hernia occurrences or recurrences. Hernias repaired using Duramesh as the sole implant were smaller (p = 0.000001) than those repaired using both Duramesh and planar mesh. CONCLUSION: There is ongoing debate about whether to repair simple and small midline ventral hernias with planar mesh or suture. Our short-term outcomes suggest Duramesh is safe in this cohort and can be technically convenient in certain situations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of outcomes across mesh placement planes in lateral abdominal wall hernia repair: a SWiM systematic review.Hernia : the journal of hernias and abdominal wall surgery · 2026
- Mesh placement and risk of reoperation for recurrence after incisional hernia repair: a nationwide register-based cohort studyHernia · 2026
- Protocol for the mesh matters project: evaluating the efficacy of suture mesh vs. planar mesh in small ventral hernia repair – a randomized, blinded multicenter studyHernia · 2026
- Clinical application of HEDI for biomechanical evaluation and visualisation in incisional hernia repairCommunications Medicine · 2026
- Mesh Placement and Risk of Recurrence and Bowel Obstruction After Primary Ventral Hernia RepairJAMA Surgery · 2026
- Comparison of medium-weight vs heavy-weight mesh in minimally invasive extraperitoneal ventral hernia repairs.Surgical endoscopy · 2026