Post-operative radiological evaluation of a bilateral hypoglossal nerve stimulation system.
A Kilgue, H-B Gehl, N Abolmaali, L-U Scholtz, C Scherl, I Todt
Department of Otolaryngology, Head and Neck Surgery, Faculty of Medicine OWL, Bielefeld University, Klinikum Bielefeld Mitte, Bielefeld, Germany. · Institute for Diagnostic and Interventional Radiology, Klinikum Bielefeld, Bielefeld, Germany.
Key points
From the paper's conclusion- Postoperative radiologic monitoring of a bilateral hypoglossal nerve stimulator is recommended. A variation of device position could be found.
Abstract
INTRODUCTION: Hypoglossus stimulation implants are a second-line option for the treatment of obstructive sleep apnea (OSA). Similar to other implants, postoperative positional evaluation serves as a quality control measure for the surgical procedure and as a reference for future adjustments. Furthermore, the impact of artifacts on the assessment of the adjacent structures might be of clinical importance. This study aimed to evaluate postoperative radiological positional implant control and artifacts of a bilateral hypoglossal nerve stimulation device. MATERIAL AND METHODS: We retrospectively evaluated radiological imaging of 11 patients on the first day after implantation of a bilateral nervus hypoglossus stimulation device. A variety of radiological imaging procedures were utilized: 8 CT scans (in sagittal and axial planes) and 11 x-ray examinations. Radiological imaging was analyzed regarding the position of the implant, anatomy, and artifacts. The age range of patients varied from 59 to 87 years (mean 69.1 years; SD 9.1 years). RESULTS: Evaluation of x-ray images did not reveal artifacts that affected the diagnostic accuracy of postoperative position control. In contrast, CT images showed artifacts in the coronal, sagittal, and axial planes, making radiological assessment more difficult. We observed a variation of device position without any effect on functionality. Defined paddle symmetry was found in 8 out of 11 cases. CONCLUSION: Postoperative radiologic monitoring of a bilateral hypoglossal nerve stimulator is recommended. A variation of device position could be found.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hypoglossal Nerve Stimulation Treatment Outcomes in Patients With Supine-Dependent Obstructive Sleep Apnea.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026
- Ramped positioning modifies the effect of cricoid and left paratracheal pressure on perceived glottic-view quality during videolaryngoscopy in adults with obesity: a secondary image-based analysis.Anaesthesia, critical care & pain medicine · 2026
- Oropharyngeal Lateral Wall Collapse as a Predictor of Hypoglossal Nerve Stimulation Response: A Systematic Review and Meta-Analysis.Ear, nose, & throat journal · 2026
- Effect of the lateral positioning on upper-airway morphology in sedated adults: a paired-design studyBMC Anesthesiology · 2026
- Oropharyngeal Lateral Wall Collapse on Drug-Induced Sleep Endoscopy as a Predictor of Hypoglossal Nerve Stimulation Response in Obstructive Sleep Apnoea-A Systematic Review.Diagnostics (Basel, Switzerland) · 2026
- The Hyoid Bone in Robin Sequence: Morphology and Position in the Context of Mandibular Distraction Osteogenesis.Plastic and reconstructive surgery · 2026