Influence of eccentric tempo on concentric performance in competitive Paralympic bench press.
Arthur Luz Dos Santos, Bárbara G Silva, Silvio S Santos, Thiago M Fidale, Frederico B Lizardo, Weverton Santos, Felipe J Aidar, Michal Wilk,
Postgraduate Program in Biomedical Engineering, Federal University of Uberlândia, Uberlândia, Brazil. · Faculty of Physical Education and Physiotherapy, Federal University of Uberlândia, Uberlândia, Brazil.
Key points
From the paper's conclusion- Conclusion Faster eccentric actions, particularly volitional tempos under 4s, were associated with greater concentric velocity and power, whereas prolonged eccentric durations reduced concentric performance in competitive Paralympic bench press.
Abstract
BACKGROUND: Short eccentric phases may enhance concentric performance in resistance exercise, but evidence under competition-specific Paralympic bench press conditions remains limited. OBJECTIVE: To investigate the acute effects of eccentric phase duration on concentric bar velocity and power output during competitive Paralympic bench press. METHODS: Thirteen competitive Para Powerlifting athletes (8 women, 5 men) performed single repetitions at 80% of 1RM under six conditions: purely concentric (CONPUR), volitional eccentric without pause (ECCVNP), volitional eccentric with a competition-valid pause (ECCVOL), and controlled eccentric phases of 2 s (ECCFAS), 4 s (ECCMED), and 6 s (ECCSLO), all including a competition-valid pause except CONPUR and ECCVNP. Peak and mean concentric velocity and power were obtained via high-speed video. Differences among conditions were analyzed with one-way repeated-measures ANOVA, Bonferroni-adjusted pairwise comparisons, and partial eta squared (ηp2) as effect size. RESULTS: Condition significantly affected peak velocity (p < 0.001, ηp2 = 0.437), mean velocity (p < 0.001, ηp2 = 0.522), peak power output (p = 0.001, ηp2 = 0.379), and mean power output (p < 0.001, ηp2 = 0.434). ECCVNP produced the highest velocity and power values, while ECCSLO produced the lowest. Eccentric duration differed significantly across eccentric conditions (p < 0.001, ηp2 = 0.988), while pause duration did not (p = 0.140, ηp2 = 0.139). CONCLUSION: Faster eccentric actions, particularly volitional tempos under 4s, were associated with greater concentric velocity and power, whereas prolonged eccentric durations reduced concentric performance in competitive Paralympic bench press.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of eccentric training on athletes' explosive power: a systematic review and meta-analysis.Frontiers in physiology · 2026
- Comparison Between Concentric-Only and Eccentric-Concentric Load-Velocity Relationships and its Derived Parameters in the Jump Squat and Bench Press Throw Exercises.Journal of strength and conditioning research · 2026
- Retrospective Analysis of Competition Attempt Variations of Elite Paralympic Powerlifters.Journal of strength and conditioning research · 2026
- Power Training Methods Across the Load-Velocity Continuum: Mechanisms, Applications, and Periodization.Sports (Basel, Switzerland) · 2026
- Effects of plyometric training with and without external load on neural adaptations and lower-limb power in male collegiate sprinters.Frontiers in physiology · 2026
- Effects of different rest intervals following postactivation performance enhancement on multiple components of performance-related fitness in elite athletes.Journal of exercise rehabilitation · 2026