Angle-torque relationship and muscular activity patterns during concentric contractions with a novel variable cam system.
Renato da Costa-Machado, Diogo L Marques, Runer A Marson, Letícia Costa de Sousa, Hugo Plácido da Silva, Hugo Louro, Daniel A Marinho, Ana Conceição
Sport Sciences School of Rio Maior, Polytechnic Institute of Santarém, Rio Maior, Portugal. · Department of Sport Sciences, University of Beira Interior, Covilhã, Portugal.
Key points
From the paper's conclusion- The VMAC® generated torque patterns comparable to isokinetic dynamometry, showing the strongest alignment at mid-ROM, supporting the use of this system to replicate natural human strength curves while highlighting the opportunity to refine cam geometry.
Abstract
INTRODUCTION: Understanding the angle -torque relationship requires recognizing that torque can differ across contraction modes. This study aimed to analyze the performance of the Variable Moment Arm Cam® (VMAC®) by examining torque production and muscle activation during concentric leg extension contractions across the full range of motion (ROM) (100°-0°) and comparing them with those obtained using an isokinetic dynamometer. METHODS: In total, 22 young men (20.55 ± 2.19 years; 175.41 ± 7.21 cm; 72.80 ± 9.90 kg; 18.00 ± 5.83% body fat; 23.63 ± 2.82 kg·m⁻2) participated in four randomized moments of torque and muscle activity assessments, two using the VMAC® and two using an isokinetic dynamometer. Torque and muscle activity data were synchronized and recorded across the entire ROM (100°-0°) and evaluated at 5° intervals. RESULTS: The VMAC® system produced strength curves that closely matched those observed when using the isokinetic dynamometer across the initial and mid-ROM joint angles (100°-35°), peaking around mid-ROM (70°-65°). Muscle activity differed across conditions while the torque production remained similar. CONCLUSION: The VMAC® generated torque patterns comparable to isokinetic dynamometry, showing the strongest alignment at mid-ROM, supporting the use of this system to replicate natural human strength curves while highlighting the opportunity to refine cam geometry.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acute adaptations in dynamic torque and torque control to practicing with known and unknown sequences of concentric and eccentric muscle contractions in healthy young adults.BMC sports science, medicine & rehabilitation · 2026
- Design and implementation of a paradigm-specific cervical manipulation simulator with objective force-angle feedback.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Biomechanics of Copenhagen Adduction Exercise and Eccentric Hip Adductor Exercises on a Novel Isokinetic Dynamometer With Within-Session Repeatability.Scandinavian journal of medicine & science in sports · 2026
- Region-specific hamstring activation and its dissociation from subjective contraction sensation during leg curl exercise at different hip flexion angles.BMC sports science, medicine & rehabilitation · 2026
- Architectural and Force-Producing Characteristics of Knee Extensor Muscles Between Alpine Skiers and Road Cyclists.Journal of strength and conditioning research · 2026
- Concurrent Validity of Isokinetic Hip and Knee Strength Measurements Using the UGO Exoskeleton in Healthy Young Adults: Cross-Sectional Validation Study.JMIR rehabilitation and assistive technologies · 2026