Development and experimental evaluation of an IoT-based closed-loop system for PM2.5 monitoring and automated electrical ionization actuation

Natima Udon, Sittichai Choosumrong, Kampanart Piyathamrongchai

Key points

From the paper's conclusion
  • The results establish Cleara-Air as an experimentally evaluated prototype framework for integrating real-time environmental sensing, automated control, and geospatial information delivery.

Abstract

Fine particulate matter (PM2.5) remains a major environmental health concern in Thailand and motivates the development of monitoring systems that can support localized, automated responses. This research presents and experimentally evaluates Cleara-Air , an integrated Internet of Things (IoT) and Web-GIS closed-loop system for real-time particulate-matter monitoring and threshold-based electrical ionization actuation. The system integrates an ESP32 microcontroller, a Sensirion SPS30 particulate sensor, a 4-channel 5V relay, a 220V AC ventilation fan, and a carbon-brush negative-anion generator, with PostgreSQL-based data storage and a responsive Web Map Application. The controller continuously acquires particulate measurements and uses 37.5 μg/m 3 as an operational PM2.5 set-point when the measured concentration exceeds this value, the relay activates the fan and ionization module, and the actuators are deactivated when the concentration subsequently falls below the set-point. The integrated workflow was evaluated through 15 repeated closed-room functional trials in which particulate concentrations were intentionally elevated near the SPS30 sensor. The evaluation examined threshold detection, actuator activation and deactivation, 15-s data transmission, database logging, and Web-GIS status visualization. The repeated tests demonstrated that the programmed sensing-processing-communication-actuation sequence operated as intended under the tested conditions, providing original experimental evidence of the functional performance of the integrated closed-loop architecture. The study evaluates system functionality rather than PM2.5 removal efficacy quantitative treatment-vs.-control experiments, reference-grade sensor calibration, and direct ozone measurements remain necessary before claims regarding mitigation effectiveness or operational safety can be made. The results establish Cleara-Air as an experimentally evaluated prototype framework for integrating real-time environmental sensing, automated control, and geospatial information delivery.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Development and experimental evaluation of an IoT-based closed-loop system for PM2.5 monitoring and automated electrical ionization actuation — Science Skim