Intraoperative flap perfusion of radial free forearm flaps is associated with postoperative flap revision in microvascular head and neck reconstruction: a retrospective cohort study.
Mark Ooms, Philipp Winnand, Marius Heitzer, Nils Vohl, Marie Sophie Katz, Johannes Bickenbach, Frank Hölzle, Ali Modabber
Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Aachen, Germany. · Department of Intensive Care Medicine, University Hospital RWTH Aachen, Aachen, Germany.
Key points
From the paper's conclusion- Intraoperative flap perfusion was associated with postoperative flap revision, with cut-off values predicting postoperative flap revision determined as minimum blood flow and hemoglobin oxygen saturation and maximum hemoglobin concentration values. These findings should be confirmed in further studies to support the implementation of prevention strategies such as intraoperative anastomosis check and closer postoperative flap monitoring for flaps at risk.
Abstract
BACKGROUND: Postoperative vascular flap compromise continues to occur in microvascular head and neck reconstruction, requiring time-consuming postoperative flap monitoring. This study assessed the association between intraoperative flap perfusion and postoperative flap revision. METHODS: Flap perfusion measurement data collected intraoperatively with the Oxygen-2-see analysis system from 296 patients reconstructed with a radial free forearm flap in the head and neck region between 2011 and 2022 were retrospectively analyzed. Intraoperative flap blood flow, hemoglobin concentration, and hemoglobin oxygen saturation at 8 and 2 mm tissue depth were compared between patients without and with postoperative flap revision and cut-off values predicting postoperative flap revision were determined. RESULTS: Intraoperative flap blood flow and hemoglobin oxygen saturation were lower and hemoglobin concentration was higher in patients with postoperative flap revision compared to patients without postoperative flap revision at 8 mm tissue depth [82.0 arbitrary units (AU) vs. 132.0 AU, p<0.001; 67.0% vs. 79.0%, p = 0.006; and 53.0 AU vs. 45.0 AU, p = 0.025]. The related cut-off values predicting flap revision for flap blood flow, hemoglobin concentration, and hemoglobin oxygen saturation were <82.5 AU, >51.5 AU, and <78.5% (sensitivity 56%, 56%, and 78%; specificity 90%, 69%, and 52%). CONCLUSIONS: Intraoperative flap perfusion was associated with postoperative flap revision, with cut-off values predicting postoperative flap revision determined as minimum blood flow and hemoglobin oxygen saturation and maximum hemoglobin concentration values. These findings should be confirmed in further studies to support the implementation of prevention strategies such as intraoperative anastomosis check and closer postoperative flap monitoring for flaps at risk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of intravenously administered norepinephrine on early postoperative tissue perfusion of radial free forearm flaps in the head and neck region - retrospective analysis in the context of continuous flap monitoring.BMC anesthesiology · 2026
- Is the Arterial Anastomosis Time a Key Predictor of Free Flap Failure in Oncological Head and Neck Reconstruction? A Prospective Cohort Study.Journal of clinical medicine · 2026
- Incidence and Risk Factors for Free Flap Compromise in Head and Neck Reconstruction: A Meta-Analysis.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026
- No early outcome benefit from additional intraoperative intravenous heparin in head and neck free flap reconstruction.Frontiers in surgery · 2026
- Intraoperative indocyanine green fluorescence angiography for the assessment of flap perfusion in head and neck oncological reconstruction: a systematic review.The British journal of oral & maxillofacial surgery · 2026
- Postoperative Hemoglobin and Transfusion Rates Do Not Influence Revision of Head and Neck Free Flap in a Cohort of 259 Patients.Head & neck · 2026