Frontiers in robotics and AI

SkinAxis: 3D force-sensing soft robotic skins balancing touch sensitivity and impact protection for safe pHRC.

Pasquale Ferrentino, Milan Amighi, Sadegh Zouelm, Théo Le Signor, Joost Brancart, Constantin Scholz, Jeroen Didden, Jelle Vanolst,

Brubotics, Vrije Universiteit Brussel and IMEC, Brussels, Belgium. · Melexis Technologies SA, Bevaix, Switzerland.

Computational

Key points

From the paper's conclusion
  • The results demonstrate that the hybrid solution achieves higher quasi-static force sensitivity ( k ε = 0.089 ) , a more reliable model for touch localization; it reaches 44.66% reduction in peak force and 18.95% reduction of transmitted energy under impact at cobot's operational velocity of 1 m s , with a maximum transmitted pressure of 1.11 MPa in accordance with ISO/TS 15066 limits.

Abstract

Physical human-robot collaboration (pHRC) requires robotic skins that simultaneously ensure impact safety, as established by ISO/TS 15066, and preserve touch sensitivity for delicate human interactions. Existing soft skins enhance compliance and multimodal sensing, but their design is rarely guided by a quantitative evaluation of the trade-off between touch sensitivity and impact mitigation, and systematic impact testing against ISO/TS 15066 limits is often absent. The SkinAxis modular soft robotic skin addresses this gap by embedding a compact 3D force sensor in the soft material, directly enabling touch localization, and using a material-based design that jointly optimizes quasi-static touch sensitivity and impact safety. This purpose is achieved by combining the mechanical properties of elastomeric materials, selected through dedicated mechanical tests, to identify a stiff elastomer that efficiently transfers forces to the sensor and a highly dissipative elastomer that absorbs impact energy. To highlight the trade-off achieved by the selected materials, two main designs are benchmarked: a single-material baseline and a hybrid patch with a compliant surface, a rigid load-transmission plate, and a stiff sensor support sleeve. The designs are compared in terms of quasi-static force sensitivity ( k ε ) , touch localization performance, and maximum pressure, as well as peak-force and transmitted-energy reduction efficiencies ( P max , η F ( - ) , η E ( - ) ), measured respectively in quasi-static compression, force-indentation, and impact experiments on a human head surrogate (PILZ PRMS setup). The results demonstrate that the hybrid solution achieves higher quasi-static force sensitivity ( k ε = 0.089 ) , a more reliable model for touch localization; it reaches 44.66% reduction in peak force and 18.95% reduction of transmitted energy under impact at cobot's operational velocity of 1 m s , with a maximum transmitted pressure of 1.11 MPa in accordance with ISO/TS 15066 limits. In parallel, finite element simulations predict the forces transmitted to the embedded force sensor in quasi-static compression and impact conditions, supporting the experimental findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

SkinAxis: 3D force-sensing soft robotic skins balancing touch sensitivity and impact protection for safe pHRC — Science Skim