Machine learning-based early detection of abnormal heart rate in critically ill patients: a real-world clinical dataset study with automated alert system integration.
Joao C Ferreira, Luis B Elvas
(ISCTE-IUL) - ISTAR-IUL, Information Sciences, Technologies and Architecture Research Center, University Institute of Lisbon (ISCTE), Lisbon, Portugal.
Key points
From the paper's conclusion- Logistic Regression was the best-performing model. Under the IQR-based definition: AUROC 0.78, recall 85.4%, precision 66.1%, F1-score 74.5%. Under the clinically standard threshold-based definition: AUROC 0.81, recall 91.7%, precision 68.8%, F1-score 78.6%. Expanded metrics (event prevalence, false-positive rate, alert burden, calibration, confidence intervals) are reported. A prototype real-time e-mail alert system was demonstrated as a feasibility proof-of-concept and reviewed informally by two cardiovascular specialists.
Abstract
INTRODUCTION: Cardiovascular diseases (CVD) are a leading global health challenge, particularly in resource-constrained settings where delayed diagnosis worsens outcomes. Abnormal heart rate (tachycardia/bradycardia) is a modifiable, independent risk factor that benefits from early, automated detection. METHODS: We used a large real-world dataset from Hospital Santa Maria, Lisbon (23,122 patients, January 2019-November 2021, spanning the COVID-19 period). Two operational outcome definitions were evaluated: (i) an interquartile-range (IQR)-based, patient-specific definition, used to compare four classifiers (Logistic Regression, K-Nearest Neighbors, Random Forest, Naive Bayes), and (ii) standard clinical thresholds for tachycardia/bradycardia, applied to the best-performing model. Following CRISP-DM, models were trained and evaluated with patient-grouped, walk-forward time-series cross-validation to prevent patient-level data leakage. RESULTS: Logistic Regression was the best-performing model. Under the IQR-based definition: AUROC 0.78, recall 85.4%, precision 66.1%, F1-score 74.5%. Under the clinically standard threshold-based definition: AUROC 0.81, recall 91.7%, precision 68.8%, F1-score 78.6%. Expanded metrics (event prevalence, false-positive rate, alert burden, calibration, confidence intervals) are reported. A prototype real-time e-mail alert system was demonstrated as a feasibility proof-of-concept and reviewed informally by two cardiovascular specialists. DISCUSSION: Recall and AUROC alone do not establish clinical utility. Key limitations include the single-centre design, substantial missingness in ethnicity/diagnosis variables, the small clinician-evaluation sample (n = 2), and pandemic-period data collection. This work is presented as a methodologically strengthened proof-of-concept, with prospective, multi-site, multi-clinician external validation identified as the necessary next step.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Incremental Value of 24-Hour Ambulatory Electrocardiogram-Derived Heart Rate Variability in Machine-Learning Prognostic Models for Heart Failure.International heart journal · 2026
- Real-Time Machine Learning Model to Predict Cardiac Arrest Within 12 Hours in Critically Ill Patients (DeepiCARS): A Confirmatory Trial and External Validation.Diagnostics (Basel, Switzerland) · 2026
- Performance evaluation of ARIMA, VAR, ANN, GRU, and LSTM for multivariate healthcare time-series prediction: a rigorous, reproducible benchmarking study with ablation analysis on MIMIC-III and eICU.Frontiers in artificial intelligence · 2026
- A comparative performance analysis of ensemble learning and regularized neural networks in cardiovascular risk prediction.Frontiers in medical technology · 2026
- External Validation of Clinical Risk Scores and Machine Learning Models for Predicting 30-Day Cardiovascular Risk After Noncardiac Surgery: The PERICARE Study.Journal of clinical medicine · 2026
- Artificial Intelligence for early detection of circulatory shock in ICU patientsarXiv · 2026